Download the DCON Utility Pro

 

The DCON Utility Pro is an easy-to-use tool designed to enable simple configuration 
of I/O modules that use the DCON protocol Pro. 
 

Step 1: Locate the DCON Utility 

 
 

The DCON Utility Pro can be obtained from the companion from the 
ICPDAS site: 

http://www.icpdas.com/download/7000/7000.htm

 

 

---------------------------------------------------------------------------------- 

Using the DCON Utility Pro to Initialize the 
M-7046(D) Module

 

The M-7046(D) is an I/O module based on the DCON protocol, meaning that you can 
use the DCON Utility Pro to easily initialize it. 
 

Step 1: Run the DCON Utility Pro 

 
 
 
 
 
 
 

Double-click the DCON Utility 
shortcut on your desktop. 
 

 
 
 

Содержание M-7046

Страница 1: ...ick Start Guide will provide information needed to get started with the M 7046 D Please also consult the User Manual for detailed information on the setup and use of the M 7046 D In addition to this g...

Страница 2: ...ervice icpdas com M 7046 D Quick Start 2 1 Understanding the Hardware Specifications and Wiring Diagrams Before installing the hardware you should have a basic understanding of hardware specification...

Страница 3: ...NIT wire to B GND 3 Connecting to the PC and the Power Supply M 7046 D series modules are equipped with an RS 485 port that can be used to connect to an RS 232 USB converter to connect the module to a...

Страница 4: ...e the DCON protocol Pro Step 1 Locate the DCON Utility The DCON Utility Pro can be obtained from the companion from the ICPDAS site http www icpdas com download 7000 7000 htm 5 Using the DCON Utility...

Страница 5: ...be displayed that will allow you to set the communication parameters as described in the table below Step 3 Search for the M 7046 D module Click Start Search button from the toolbox to search for the...

Страница 6: ...M 7046 D After clicking on the name of the module in the list a dialog box would be display Step 5 Initialize the M 7046 D module Set the Address field in the dialog box to 1 and then click Setting b...

Страница 7: ...00036 10001 10004 DI Value R 00065 00068 DI Latch High Value R 00069 00072 DO Latch High Value R 00097 00100 DI Latch Low Value R 00101 00104 DO Latch Low Value R 00264 Write 1 to clear latch values F...

Отзывы: