LRA-900-E (Ethernet to LoRa Radio Modem) Firmware Update via Ethernet
Version 1.0.0
Page
:
7
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved E-mail: [email protected]
Step 9:
Power-on reset
the LRA-900-E module in
“Init Mode”
to initiate the update.
Step 10:
Confirm that the two MAC addresses (factory-default) listed in the Command Prompt
window,
“Waiting request from MAC x.x.x.x”
and
“BOOTPREQ from MAC: x.x.x.x”
,
are the
same, as indicated in the image below. If these addresses do not match, the update can
below for more details.
Step 11:
Once the update is complete (i.e., when the progess indicator reaches 100%), set the
“Init
Switch”
to the
“Run”
position.
Step 12:
Power-on reset
the LRA-900-E module to operate the module in
“Run Mode”
.
Step 13:
In the eSearch Utility, search for the LRA-900-E module again to verify that it is
functioning correctly.
Note that the network settings for the module may need to be
reconfigured after updating the firmware. Refer to
above for more
details.
Step 14:
Click the name of the LRA-900-E module to highlight it.