manualshive.com logo in svg
background image

 

 

iNS-316   
User Manual 

 

Ver. 1.0.0, April. 2023

 

 
 
 
 

 

W

ARRANTY

 

All products manufactured by ICP DAS are warranted against 

defective materials for a period of one year from the date of 

delivery to the original purchaser. 

 

W

ARNING

 

ICP DAS assumes no liability for damages consequent to the use 

of this product. ICP DAS reserves the right to change this manual 

at any time without notice. The information furnished by ICP DAS 

is believed to be accurate and reliable. However, no 

responsibility is assumed by ICP DAS for its use, nor for any 

infringements of patents or other rights of third parties resulting 

from its use. 

 

C

OPYRIGHT

 

Copyright ©  2021 by ICP DAS. All rights are reserved. 

 

T

RADEMARK

 

Names are used for identification only and may be registered 

trademarks of their respective companies. 

 

C

ONTACT 

U

S

 

If you have any questions, please feel free to contact us via email 

at:   

[email protected] 
 

 

S

UPPORT

 

iNS-316 

Содержание iNS-316

Страница 1: ...t any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents...

Страница 2: ...4 1 Home 17 4 2 Schedule 19 4 3 Network 20 4 4 MQTT 26 4 5 SNMP 27 4 6 Filter 28 4 7 Changing Password 29 4 8 Logout 30 4 9 MQTT 31 4 9 1 Connectivity Settings 32 4 9 2 Publication Settings 33 4 9 3 R...

Страница 3: ...Status of the Input Read DI values 47 7 2 3 03 0x03 Read the Holding Registers Read AO Readback values 48 7 2 4 04 0x04 Read the Input Registers Read AI values 49 7 2 5 05 0x05 Force a Single Coil Wri...

Страница 4: ...er Ethernet PoE devices such as wireless access points APs IP cameras and IP phones to the network In compliance with the IEEE 802 3at standard each PoE port ensures the PSE function and provides up t...

Страница 5: ...ing List The shipping package includes the following items Quick Start x 1 iNS 316 Note If any of these items are missing or damaged please contact the local distributor for more information Save the...

Страница 6: ...t allows users to easily configure monitor and control the module from a remote location using a web browser 2 Power On Off Schedule An individual power on off schedule is provided for each PoE port o...

Страница 7: ...E port you can configure the schedule through a web browser to reset your devices regularly and keep them working in good condition 4 Dual Redundant Power Input The iNS 316 has dual redundant power in...

Страница 8: ...g protection it also provides user defined PoE power output limit so that if the PD device is damaged or short circuited the power will be cut off PoE in time to protect other devices 7 Advanced Ether...

Страница 9: ...r Color status Description P1 Green On Power is being supplied to power input PWR1 Off Power is not being supplied to power input PWR1 P2 Green On Power is being supplied to power input PWR2 Off Power...

Страница 10: ...rking 3 PoE Status Indicator iNS 316 has 16 Port 10 100Mbps PoE Port independent PoE status LED for per port when PoE detect the PD device LED will turn on LED Indicator Color Stats Description PoE Or...

Страница 11: ...Over Ethernet Energy Efficient Ethernet EEE as per 802 3az this provides power savings during idle network activity Processing Type Store forward MAC Addresses 16K Frame Buffer Memory 4Mbit Isolation...

Страница 12: ...All Rights Reserved 12 2 3 Ethernet and PoE Pin Out The pinout follows the Alternative A of IEEE 802 3af 802 3at standards Please see the details in the following table Pin No Ethernet PoE 1 Tx V 2 T...

Страница 13: ...sure that the network settings on the Host PC have been correctly configured and are functioning normally Ensure that the Windows firewall or any Anti Virus firewall is properly configured to allow in...

Страница 14: ...te at https www icpdas com en product guide Software Utility_Driver eSearch__Utility Step 2 Install the eSearch Utility Follow the instructions in the eSearch setup wizard to complete the installation...

Страница 15: ...55 0 0 Step 5 Assign new network settings and then click the OK button Enter the relevant values for the IP Address Subnet Mask Gateway etc and then click the OK button The new settings will take effe...

Страница 16: ...a web browser Step 8 Change password upon first login The default password for logging in to the iNS 300 web page is Admin You will be prompted to change your password upon first login or when the pa...

Страница 17: ...configuring and managing module settings through a browser 4 1 Home The Home page is the startup page when you log into the module It displays detailed information about the module and the connection...

Страница 18: ...mit W this function can not used for CDPL mode Current mA The current of connected PoE devices unit mA Watt W The power consumption of connected PoE devices unit W TEMP Display iNS 316 PoE Port inside...

Страница 19: ...edule for PoE powered device s in a week The first section provides PoE Port select schedule Enable Disable and reset delay configure interface Whan Power On Schedule set to Enable and Power schedule...

Страница 20: ...ve a dynamic IP address from a DHCP server or select static IP to manually assign an IP address to the module here Item Description Address Type Static IP Manually set the IP Address Subnet Mask and D...

Страница 21: ...from the Address Type drop down menu Step 2 Click the Update Settings button to complete the configuration Static IP Configuration If Static IP is selected you have to assign an IP address a subnet m...

Страница 22: ...the UDP configuration function Web Auto logout Set the automatic logout time The user will be log out after the predetermined period of inactivity on web interface has elapsed Alias Name Assign the a...

Страница 23: ...Default Settings Step 1 Click the Restore Defaults button Step 2 Click OK on the pop up dialog box Step 3 Search the iNS 300 series module in the eSearch Utility to confirm if the factory default sett...

Страница 24: ...right 2022 ICP DAS CO Ltd All Rights Reserved 24 Rebooting the Module Step 1 Click the Reboot button in the right field of Force Reboot Step 2 After the module restarts reload the web interface and lo...

Страница 25: ...rmware by clicking the Reboot button in the Firmware Update section via the network without manual adjustment Note that the iNS 300 series module needs to be connected to the same network as your comp...

Страница 26: ...ty Settings for more details about the setting Publication Settings Refer to Section 4 8 2 Publication Settings for more details about the setting PoE Status Refer to Section 4 9 MQTT PoE Status for m...

Страница 27: ...NMP basic parameters and Trap IP Address check the Enable SNMP item and click the Update Settings button to enable the function Note Modify the SNMP Enable status please reboot the iNS 316 to activate...

Страница 28: ...he Allow IP List only clients that have an IP address within the filter list can access the iNS 300 series module Item Description Add IP to the List Enter the new IP address to the Allow IP List Dele...

Страница 29: ...assword on the Password page Step 1 Enter your current password in the Current password field Step 2 Enter your new password in the New password field 1 12 alphanumeric characters are allowed Step 3 E...

Страница 30: ...iNS 316 User Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 30 4 8 Logout Click Logout on the navigation bar to log out of your account It redirects you to the login page...

Страница 31: ...g and receiving of all messages between a Publisher and a Subscriber The Publisher is the entity that publishes the topic and message the Subscriber is the entity that receives the updated messages fr...

Страница 32: ...eter is used when the MQTT broker requires authentication The length should be no more than 63 characters N A Reconnection Interval The time interval between attempts by the iNS 300 module to connect...

Страница 33: ...ised settings to the iNS 300 Switch Item Description Defaults Publication Retain Check this option to ensure that the message is retained once it is published Disabled Cycle The time interval that the...

Страница 34: ...The QoS for the Last Will and Testament message 0 At most once Topic The Topic Name for the last will and Testament message The length should be no more than 63 characters N A Message The Last Will a...

Страница 35: ...ble describes the parameters contained in the MQTT Outputs section Item Description Defaults Subscribe The PoE Enable status will change with messages updated by subscribed topics Disabled Sub Topic N...

Страница 36: ...epends on the Cycle settings Check the box to enable and uncheck it to disable the function Disabled Publish On Change A message will be published when the state of the corresponding PoE Enable is cha...

Страница 37: ...s enabled iNS 300 series can actively send messages to the SNMP manager to keep track of data when the I O status of the module changes or restarts The detailed description is as follows 4 11 1 SNMP C...

Страница 38: ...0 0 Manager Trap IP 2 Set the IP address of Trap IP 2 0 0 0 0 Generic Trap Select to enable the Cold Start or Warm Start function Disabled Enable SNMP Select the box to enable the SNMP communication...

Страница 39: ...o reboot the attached devices The iNS 316 will check the schedule every hour on the hour If the checkbox for reset function is selected the power on a POE port will be turned off and turned on again f...

Страница 40: ...Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 40 table provide bulk selection functionality Click Toggle On Off or Toggle Reset will select all time at a day Click 0 to 23 will select all d...

Страница 41: ...efined by af at sets the corresponding power upper limit When the device load exceeds too much it will power off and retry to protect the device Please refer to the following table for the class class...

Страница 42: ...316 provided broadcast storm protect function after checking broadcast storm filter in home page the iNS 316 will actively control the broadcast type packets packet Destination Address is MAC FF FF FF...

Страница 43: ...ode Wizcon ElUTIONS and Wonderware etc can be used to easily integrate serial devices via the Modbus protocol 7 1 What is Modbus TCP IP Modbus is a communication protocol that was developed by Modicon...

Страница 44: ...data to be returned and an error checking field The Modbus TCP Message Structure The Leading 6 bytes of a Modbus TCP Protocol Query Transaction identifier Assigned by the Modbus TCP master client Prot...

Страница 45: ...een correctly transmitted Code Function 01 0x01 Read Coils status Readback DO values 02 0x02 Read Input Status Read DI values 03 0x03 Read Holding Registers Readback AO values 04 0x04 Read Input Regis...

Страница 46: ...Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Points Channels 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 2...

Страница 47: ...te Byte 03 Low byte 04 05 Number of Points Channels 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 247 01 Function Code 1 Byte 0x02...

Страница 48: ...yte 1 to 247 01 Function Code 1 Byte 0x03 02 03 Starting AO Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Registers Channels 2 Byte Word Count Byte 04 high byte Byte 05 Low byte Re...

Страница 49: ...unction Code 1 Byte 0x04 02 03 Starting AI Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Registers Channels 2 Byte Word Count Byte 04 high byte Byte 05 Low byte Response Byte Descr...

Страница 50: ...3 Low byte 04 05 Output Value 2 Byte 0xFF 00 sets the output to ON 0x00 00 sets the output to OFF Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byt...

Страница 51: ...Byte Byte 02 high byte Byte 03 Low byte 04 05 Output Value 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 247 01 Function Code 1 By...

Страница 52: ...te count 1 Byte n Points 7 8 07 Output value n Byte A bit corresponds to a channel A value of 1 for a bit denotes that the channel is ON while a value of denotes that the channel is OFF n 1 Byte 07 da...

Страница 53: ...Registers Channels 2 Byte Byte 04 high byte Byte 05 Low byte 06 Byte count 1 Byte n Points 7 8 07 Register Values n Byte n 1 Byte 03 high byte n 2 Byte 04 Low byte n m Byte m 1 high byte Byte m 2 Low...

Страница 54: ...W 00042 1 Ethernet Broadcast storm filter 0 Disable 1 Enable R W 3xxxx AI address Base 0 Address CH Description Range Access Type 30000 30015 16 PoE Port Current mA 2 Byte DEC mA R 30032 30048 16 PoE...

Страница 55: ...ts Reserved 55 4xxxx AO address Base 0 Address CH Description Range Access Type 40000 40015 16 PoE Host Power output Limit 1 4W 2 7W 3 15 5W 4 30W R W 40032 1 Ethernet Link status Configure 0 auto neg...

Страница 56: ...iNS 316 User Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 56 Revision History Revision Date Description 1 0 0 April 2023 New...

Отзывы: