(b) If X-aixs command is executing and moving toward CCW/BW
direction, X-axis will immediately stop when LS11 is touched. To
release this protection as long as X-axis move toward CW/FW
direction.
(c) If Y-aixs command is executing and moving toward CW/FW direction,
Y-axis will immediately stop when LS24 is touched. To release this
protection as long as Y-axis move toward CCW/BW direction.
(d) If Y-aixs command is executing and moving toward CCW/BW
direction, Y-axis will immediately stop when LS21 is touched. To
release this protection, as long as Y-axis move toward CW/FW
direction.