I-8017/I-9017 Series I/O Module User Manual
V3.0.3
P.62
Parameters
iSlot
Specific slot number (0 - 7), except range of slot is number 1 ~ 8 for LinPAC.
iGain
Specifies the input range
0: +/- 10.0V
1: +/- 5.0V
2: +/- 2.5V
3: +/- 1.25V
4: +/- 20mA
*iGainValue
[Output]Specifies the calibrated Gain value
*iOffsetValue
[Output]Specifies the calibrated Offset value
Return Values
Refer to Appendix A: “Error Code” for more details.
Examples
[C++]
Int slot,Gain;
unsigned short GainValue;
short OffsetValue;
short pac_i8017HW_ReadGainOffset_Info(slot, Gain,& GainValue,& OffsetValue);
[C#]
Int slot,Gain;
unsigned short GainValue;
short OffsetValue;
pac8017HWNet.pac8017HW.GainOffset_Info(slot, Gain, ref GainValue, ref OffsetValue);
Содержание I-8017 Series
Страница 14: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 14 1 2 Pin Assignments 1 2 1 I 8017HW ...
Страница 15: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 15 1 2 2 I 8017HCW ...
Страница 16: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 16 1 2 3 I 8017DW ...
Страница 17: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 17 1 2 4 I 9017 ...
Страница 18: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 18 1 2 5 I 9017 15 ...
Страница 19: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 19 1 2 6 I 9017C 15 ...
Страница 26: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 26 1 5 3 I 9017C 15 ...
Страница 55: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 55 ...
Страница 83: ...I 8017 I 9017 Series I O Module User Manual V3 0 3 P 83 Click Restore Defaults button ...