background image

 

 

I-7232D CANopen/Modbus RTU Quick Start User Guide (Version 1.1,March/2006, I-7232D)  -----

 

The I-7232D 

CANopen

/Modbus  Gateway

 

Quick Start User Guide 

1.   Introduction 

This user guide describes how to implement the I-7232D module into 

users’ applications in a quick and easy way. Therefore, it only provides the 
basic instructions. If users want to know more detail information about the 
I-7232D, please refer to the I-7232D user manual in the product CD or 
download it from following web site:  

 

http://www.icpdas.com/download/can/index.htm

 
 
The purpose of this manual is focused on helping users to quickly 

familiarize themselves with the I-7232D module. Users can apply the I-
7232D module as follows. 

 

CANopen 

Device

PISO-CAN200/400

CPS_Modbus RTU

Gateway

 

C

A

N

o

p

e

n

CANopen

Salve

I-8421

PISO-CPM100

RS-485

Modbus RTU

(M-7000)

Modbus RTU 

Master

PC

 

 

 

 

 

 

 

 

Содержание I-7232D

Страница 1: ...ns If users want to know more detail information about the I 7232D please refer to the I 7232D user manual in the product CD or download it from following web site http www icpdas com download can ind...

Страница 2: ...ps 3 125 K bps 9600 bps 4 250 K bps 19200 bps 5 500 K bps 38400 bps 6 800 K bps 57600 bps 7 1000 K bps 115200 bps Bypass CAN Bus Connector 7 segment LED RS 232 Port connect to PC Reserve for further u...

Страница 3: ...I 7232D CANopen Modbus RTU Quick Start User Guide Version 1 1 March 2006 I 7232D 3 4 How to Start...

Страница 4: ...ng the CANopen Modbus RTU Gateway Utility please connect the COM1 of the I 7232D with the available COM port of your PC Also connect the configured Modbus RTU modules with the COM2 of the I 7232D The...

Страница 5: ...ure will be displayed Then click the connect button Note When the CAN_MRU exe can t get the configuration information from the EEPROM it may response a Warning dialog as follows This situation may be...

Страница 6: ...atch with the communication parameters of Modbus RTU modules Afterwards click the Next button to next step Step 8 You have to input the Modbus device NodeID Relay Address Register Relay Address and Da...

Страница 7: ...nformation please select the instance number corresponding to this device and click the Delete button the device information will be removed Users can click on the PDO Information or Modbus Informatio...

Страница 8: ...7232D Step 10 Turn off the I 7232D and remove the wire between the Init pin and GND pin of the I 7232D Then power on the I 7232D When the I 7232D has finished the initialization the RUN LED on the I...