I-7063 Power Relay Output & DI DAQ Module - QuickStart (Oct/2017)  

ICP DAS USA, Inc.

 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

I-7063 

Power Relay Output & Isolated Digital Input 

Data Acquisition Module 

Quick Start Guide 

 
 

Product Website:  

https://www.icpdas-usa.com/i_7063_i_7063d.html

 

http://www.icpdas-usa.com/dcon_utility_pro.html

  

 

1. Introduction 

 

I-7063 is intelligently designed to provide signal conditioning system 
monitoring and safe value settings. I-7063 is a cost-effective solution for a 
wide range of valuable industrial control signals and systems. The DCON 
utility can help users to configure and test I-7063 power relay output 
module. Plenty of library functions and demo programs are provided to let 
users develop programs easily under Windows, Linux and DOS operating 
systems. The communication interface is modbus protocol via RS-485. 
Users may mount the modules on a DIN rail, panel or wall. Modules have a 
screw-terminal block to connect to the signals. 
 

2. Terminal Assignment 

 

 

Содержание I-7063

Страница 1: ... to provide signal conditioning system monitoring and safe value settings I 7063 is a cost effective solution for a wide range of valuable industrial control signals and systems The DCON utility can help users to configure and test I 7063 power relay output module Plenty of library functions and demo programs are provided to let users develop programs easily under Windows Linux and DOS operating s...

Страница 2: ...DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 3 Block Wiring Diagram 4 Default Settings Default settings for the I 7063 DIO modules are as follows Module Address 01 DIO Type Type 40 Baud Rate 9600 bps Checksum disabled ...

Страница 3: ...the module follow the steps below 1 Connect the analog output 2 Connect the module to the RS 485 network using the DATA and DATA terminals If the host is only equipped with an RS 232 interface then an RS 232 to RS 485 converter will be required 3 Connect the module to the power supply using the Vs and GND terminals Note that the voltage supplied should be in the range of 10 to 30V DC ...

Страница 4: ... 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 4 4 Open DCON utility pro click on COM port first icon It can select multi options such as Baud Rate Protocol Checksum and Format to search module The default settings for the module can be found in Section 3 Click OK after selecting the COM port setting ...

Страница 5: ...a com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 5 DCON utility pro will search for the selected COM port according the setting previously set DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules 6 Configuration I O module setting on PC ...

Страница 6: ...ve Suite 200 Lomita CA 90717 6 7 For I 7000 modules DCON utility pro terminal can send command to the module See user manual Sections 2 for details command Configure the module sending the AANNTTCCFF command See user manual Section 2 for details Read data from the input channels send either the AA or AAN command to the module ...

Страница 7: ... ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 7 8 If user doesn t know command user can select Address and ID it will show some refer commands as below User can select necessary command to test or debug modules ...

Отзывы: