![ICP DAS USA I-2533 Скачать руководство пользователя страница 2](http://html2.mh-extra.com/html/icp-das-usa/i-2533/i-2533_quick-start_3556927002.webp)
I-2533 Quick Start (ver. 2.0, 2021/11/09) -----2
1. Introduction
This quick start helps users to apply the I-2533 in
users
’ applications quickly. If users need the details
of I-2533 or the difference about the meaning of the
[V2] mark, please refer to the I-2533 user manual.
Users can free download it from the website below.
https://www.icpdas.com/en/download/index.php?model=I-2533
2. Hardware Installation
Before using I-2533, some things must be done.
1. Prepare one pair of I-2533.
2. Set the CAN baud rate of each I-2533 by using rotary switch. You
can refer to the following table for details. (If you set the rotary
switch to
“A”, please use utility tool to do the configuration before.)
8
7
0
C
4
2
1
F
D
B
9
5
3
A
6
E
Rotary switch for
CAN baud rate
Switch Value
Description
0
Set baud rate to 10 kbps
1
Set baud rate to 20 kbps
2
Set baud rate to 50 kbps
3
Set baud rate to 80 kbps
4
Set baud rate to 100 kbps
5
Set baud rate to 125 kbps
6
Set baud rate to 250 kbps
7
Set baud rate to 500 kbps
8
Set baud rate to 800 kbps
9
Set baud rate to 1 Mbps
A
Set baud rate to user-defined baud rate
which is configured by I-2533 utility.
B~D
Not-available
E
Update firmware
F
Set I-2533 into configuration mode.