ICP DAS USA GW-7553 Скачать руководство пользователя страница 6

 

Click <Online->Download> to download the setting into PROFIBUS Master 
station  
 

 

Set the network configuration of the GW-7553 

1.

 

Open MiniOS7 utility and press “F12” to find IP address of GW-7553. 

2.

 

Open web browser (ex. IE). Enter IP address of the GW-7553 in the 
Address field and press “

Enter

” to connect to GW-7553, and then 

enter default password (“icpdas”) to login to GW-7553 in Login page.   

3.

 

Click “IP Setting” to set the network configuration of the GW-7553 
(please refer to user manual section 6.2). The network configuration of 
the GW-7553 must have the same domain and different IP with the PC 
(ex: PC’s IP=192.168.0.106, MASK=255.255.0.0; GW-7553’s 
IP=192.168.0.107, MASK=255.255.0.0). 

4.

 

Press “Save to Device” to save IP setting to EEPROM of GW-7553 
and restart GW-7553. 

 

 

1

2

3

4

 

GW-7553 PROFIBUS/Modbus TCP Gateway Quick Start

 (Version 1.10, May/2012)      

PAGE

Содержание GW-7553

Страница 1: ...pplication example of PROFIBUS to Modbus TCP In this example the GW 7553 acts as a Modbus TCP Slave device When the GW 7553 module receives a write DO Modbus command from PC s Ethernet Port the GW 755...

Страница 2: ...en the cover as shown in the below The range of DIP switch is 0 126 here we set GW 7553 module s DIP switch to 1 LED status indicator LED Status Description flash When the GW 7553 is a Modbus Slave de...

Страница 3: ...nfigurations 3 Finally change your DP master from offline state to operate state The GW 7553 will be initialized If there is no error occurs GW 7553 proceeds into data exchange state At the meantime i...

Страница 4: ...GW 7553 The user needs to change Modbus Type to Slave Modbus Format to Modbus TCP and use the default value in the other parameters in this example Please refer to user manual section 4 3 The Configu...

Страница 5: ...s In this example we configure a System Setting module an Output Relay Coil 2 Byte module and an Input Relay Coil 2 Byte module as follows Double click GW 7553 s icon to enter Slave configuration dial...

Страница 6: ...r default password icpdas to login to GW 7553 in Login page 3 Click IP Setting to set the network configuration of the GW 7553 please refer to user manual section 6 2 The network configuration of the...

Страница 7: ...he user needs to input command 01 0F 00 00 00 10 02 FF FF here and click Send Command button to send Modbus command and then MBTCP can receive response message 01 0F 00 00 00 10 The user can find byte...

Страница 8: ...ut command Send command to read DI of the GW 7553 again Now the user can input command 01 02 00 00 00 10 in MBTCP and click Send Command button to send Modbus command again Then MBTCP can receive resp...

Отзывы: