7. Troubleshooting

 

Item 

Trouble state 

Solution 

EXT LED is off without Li-battery 

Please check the external power and wire 

connection. 

STA is always on 

Check SIM card   

Check Antenn   

Check the GSM signal strength   

GT-530 Utility can not connect to 

GT-530 

Check STA LED blinking every 1 sec   

Check com port connection and baurd rate   

setting  

After event triggering, users can not 

receive SMS. 

Check DI connection 

Check phone number and format   

Check DI event is enabled in GT-530 Utility   

Counter value is abnormal 

Check wire connection 

Check the counter signal is at 5~40Hz. 

Check the DI mode setting. Must be counter 

mode. 

The content of received SMS is 

abnormal.  

Please select the correct language to set the 

content of SMS in utility. If you want to 

transfer Unicode char, select the language 

supporting UCS2. 

The time of receiving SMS is 

abnormal.  

1. The time in GT-530 is abnormal. Setup the 

time of GT-530 by utility. 

2. The battery of RTC is low. Change the silver 

battery of RTC. After changing the battery, 

set the time of GT-530. 

STA led is blanking per 50 ms 

The pin code is wrong. The login windows 

would show the field to input PIN or PUK code

Forget Password 

Use SMS command to get the password. 

 

 

 

GT-530 User Manual, Version 1.0, August 2009 

48/48 

Содержание GT-530

Страница 1: ...GT 530 user manual v1 0 GT 530 Intelligent SMS alarm controller User Manual v1 0 High Quality Industrial Data Acquisition and Control Products Publication Aug 2009 Ver 1 0...

Страница 2: ...ny time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use or for any infringements of patents or o...

Страница 3: ...tility 13 3 1 Install NET Compact Framework 13 3 2 Install GT 530 Utility 15 4 GT 530 Utility operation 18 4 1 Main menu 19 4 2 Operation Language 21 4 3 Login 22 4 4 Main parameter 24 4 5 SMS Recorde...

Страница 4: ...manual v1 0 5 6 PASS Password inquiry 46 6 Send Receive SMS by com port 47 6 1 Send data to COM port of GT 530 by SMS command 47 6 2 Send SMS from COM port 47 7 Troubleshooting 48 Publication Aug 2009...

Страница 5: ...allowing you to use your mobile phone to monitor and control your business from any location Its alarm facilities provide a flexible way to distribute critical alarm information to any number of mobi...

Страница 6: ...nter 2 DO 2 RS232 port z Digital input support NC normal close NO normal open Counter modes z Peroidic SMS report z Alarm SMS triggered by DI trigger or exceed Counter preset limits z Support simple c...

Страница 7: ...GT 530 user manual v1 0 Application 2 Home security Application 3 Remote maintenance Application 4 SMS Tunnel Communication GT 530 User Manual Version 1 0 August 2009 3 48...

Страница 8: ...wer or Li battery On Voltage 3 5 24VDC Off Voltage 1V Max Output D O 2 Channel Open collector output 500mA 24VDC 2 digital output channels Output type Open Collector NPN Load Voltage 24V Max Load Curr...

Страница 9: ...h Li ion battery backup Option 1200 mAh Mechanical Casing Plastic Flammability UL 94V 0 materials Dimensions W x H x D 91 mm x 132 mm x 52 mm Installation DIN Rail Environment Operating Temperature 25...

Страница 10: ...of the external power input DI DO Terminal No Pin Assignment 01 DI0 02 DI1 03 DI2 04 DI3 05 DI4 06 DI5 07 DI6 08 DI7 09 DI8 DI 10 DI9 11 DO0 12 DO1 DO 13 DO PWR DI DO 14 Ext GND COM Port Power Input...

Страница 11: ...GT 530 user manual v1 0 2 3 Diemensions GT 530 User Manual Version 1 0 August 2009 7 48...

Страница 12: ...e NC normal close The NC mode is used as normal close in relay application as follows The logical value of DI is 1 when the relay is ON in normal use When the relay is triggered as relay open the logi...

Страница 13: ...plication as follows The logical value of DI is 0 when the relay is close in normal use When the relay is triggered as relay close the logical value of DI is 1 and the SMS would be sent If the counter...

Страница 14: ...wer is active The external power is not active on off B STA Orange System LED is to indicate if the GT 530 is normal or fail Condition External power Normal GSM Fail PIN code is wrong On Blanking 1 se...

Страница 15: ...tery to GT 530 F It is needed to wait for 30 50 seconds to search the GSM base and register to the ISP After finishing the process GT 530 would be in normal operation mode and the STA LED would blank...

Страница 16: ...power supplying to GT 530 is from Li Battery If the voltage of Li Battery is lower than the preset limit GT 530 can send the SMS message to inform the users Note A new Li Battery can supply power to...

Страница 17: ...Framework 2 0 or above in the PC the section 3 1 can be omitted 3 1 Installing NET Compact Framework A Plug shipment CD into the PC B Execute GT 530 Utility dotnetfx20 exe C The install figure is as...

Страница 18: ...GT 530 user manual v1 0 3 The installation process would be going 4 After finishing the installation press Finish to exit the program GT 530 User Manual Version 1 0 August 2009 14 48...

Страница 19: ...B Execute GT 530 Utility SMSUtilitySetup exe C The installation figure is as follows 1 Press Next to start the installation procedure 2 Select the installation path The default path is C Progrm Files...

Страница 20: ...0 user manual v1 0 3 Input the name shown in All Programs Press Next to the next step 4 After finishing the installation procedure press OK to the next step GT 530 User Manual Version 1 0 August 2009...

Страница 21: ...er manual v1 0 5 Press Finish to finish the installation procedure 6 Launch GT 530 Utility from the start menu Start All Programs GT 530 Utility GT 530 Utility GT 530 User Manual Version 1 0 August 20...

Страница 22: ...g per 1 sec Normal mode Blanking per 50 ms The pin code is wrong The login windows would show the field to input pin or PUK code 2 Confirm the RS232 connection between GT 530 and PC is correct Users c...

Страница 23: ...Tradition and Simplified Chinese interface Users can select which language interface they want from the Language item The language setting would be influencing on the encode of SMS 4 File There are i...

Страница 24: ...the information of the last and next time of the return report 4 Counter Value Inquire and set the counter value 5 Change Password Change the login password 6 DO Control DI status Display the status o...

Страница 25: ...ded on the selected language interface The format of SMS accords to the selected language If the 7 BITS format is set the maximum characters can be sent in SMS is 140 If UCS2 the maximum number is 70...

Страница 26: ...GT 530 If the pin code in GT 530 is not correct the STA led would be blanking per 50 ms and GT 530 utility would ask for users to input Pin or PUK code 1 Asking for inputting PIN code If the PIN code...

Страница 27: ...of times for inputting the wrong PUK code is more than allowed number the SIM card would be ineffective forever Therefore it is important to input the correct PUK code If the PIN or PUK code is correc...

Страница 28: ...main menu 4 4 1 Phone Periodic report Alarm The following page is Phone Periodic Report Alarm Users can refer the explanation below 1 Machine ID The device ID would be shown in the report and alarm S...

Страница 29: ...te SS second DI0 DI5 The counter values of DI0 DI5 If these DI channels are not set as counter mode the counter value would be zero Note If CRPT function is enabled and the return time is changed the...

Страница 30: ...hine ID Report Date Report Time Event Message ALARM Indicate alarm report Machine ID Device ID Report Date Report date The format is YYYYMMDD YYYY year MM month DD day Report Time Report time The form...

Страница 31: ...530 is abnormal This function can not be disabled It could make the wrong timing for report and the cause is the silver battery of GT 530 is abnormal After changing the silver battery the time of GT...

Страница 32: ...ggered signal 0 9999 seconds 4 DO ON This function enable DO output when DI event is triggered 5 DO ch Set the DO channel 6 Time sec Set the output time of DO channel 0 999 seconds If the power is jus...

Страница 33: ...ing back the setting of device parameters from par file and displaying in Device parameter window When press import button a file selection window would pop up for users to choice the par file B Expor...

Страница 34: ...maximum number of CRPT report record is 64 2 Save Save these records to a file csv 3 Delete all Delete all CRPT report records from GT 530 Text field 1 No The number of RTCP records 2 Report time CRPT...

Страница 35: ...Report record In this page users can inquire all event report of GT 530 The explanation is below Operation 1 Read Read all the CRPT report from GT 530 The maximum number of CRPT report records is 64 2...

Страница 36: ...time would be updated 2 Set Set the GT 530 time according the Device Time field After setting the time successfully the information of GT 530 time and CRPT report time would be updated 3 Read Read ba...

Страница 37: ...he maximum is 999999999 This field is enabled when DI is set as counter mode 4 Counter Alarm Enable the counter alarm 5 Alarm Value Counter alarm value current value alarm value This field can not be...

Страница 38: ...s password is also applied in SMS command to GT 530 These SMS commands is described in chapter 5 Text field 1 Old password Input the current password 2 New password Input the new password maximum 12 c...

Страница 39: ...the status of DIs Text field 1 DI0 DI9 DO0 DO1 Grey the voltage logic is high Red the voltage logic is low Operation 1 Read Read back the status of DI0 DI9 and DO0 DO1 from GT 530 2 DO0 DO1 ON Set th...

Страница 40: ...eeds to open the external power when using utility to configure GT 530 2 Level Show the percentage of battery volume If the battery is not connected to GT 530 The value is about 60 3 Voltage The volta...

Страница 41: ...11 Signal Quality This window can show GSM signal strength Text field The strength is divided into 5 sections shown in percentage Operation 1 Read Read the GSM signal strength GT 530 User Manual Vers...

Страница 42: ...how the version of Utility and firmware Text field 1 Firmware version show the version information of GT 530 s firmware 2 Utility version show the version information of GT 530 s utility Operation Rea...

Страница 43: ...T 530 as factory settings including password The steps are below 1 Connect COM3 TX and COM3 RX 2 Make sure the STA led is blanking per 1 sec 3 Select the Recover to Factory Settings 4 13 2 Reset GT 53...

Страница 44: ...numbers set in GT 530 These phone numbers must be set to have Allowed authority If the phone number is not in the list GT 530 would not reply to any command Command Table SMS command Description DTIME...

Страница 45: ...our MM minute SS second Example Set the time as 2009 04 10 10 03 00 TIME 000000 20090410 100300 Inquiry the time TIME 000000 3 Response MID TIME Result YYYYMMDD HHMMSS MID Machine ID TIME Command name...

Страница 46: ...r PLUS mode 0 999 seconds Example Set DO1 output to on DOC1 000000 ON Set DO1 output to on during 20 seconds DOC1 000000 PLUS 20 3 Response MID DOCn Result CMD Second MID Machine ID DOC command name n...

Страница 47: ...ER The format is wrong or authority is not allowed DI0 The DI0 counter value If the DI is not set as counter the value is 0 DI1 The DI1 counter value If the DI is not set as counter the value is 0 DI2...

Страница 48: ...Result DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DO0 DO1 MID Machine ID DIV command name Result command result OK command successflly NO the password is wrong ER The format is wrong or authority is not...

Страница 49: ...000000 3 Response MID BAT Result Pext Percent Voltage MID Machine ID BAT command name Result command result OK command successfully NO the password is wrong ER The format is wrong or authority is not...

Страница 50: ...be set the authority of SMS Command 2 Request Inquiry PASS Example Inquire the password of GT 530 PASS 3 Response MID PASS Result Password Password MID Machine ID PASS command name Result command resu...

Страница 51: ...ommand header is The first setting phone number just has the authority to use this function with the Allowed enabling The command support 7 Bits format Command Message Message The message is sent to c...

Страница 52: ...Check wire connection Check the counter signal is at 5 40Hz Check the DI mode setting Must be counter mode 6 The content of received SMS is abnormal Please select the correct language to set the conte...

Отзывы: