3.2. Pin Assignment 

 

„

  External Power supply and signals connection 

J1: 

 

 

„

  Additional FRnet signal connectors 

 

All FRnet A signals are internally connected together, and all 

FRnet B signals are connected together, too. Following two 

connectors are used for FRnet quick connection. 

 

CN3/CN4 

     

 

 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Содержание FR-32R

Страница 1: ...he right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not f...

Страница 2: ...e of FR 32R 5 3 2 Pin Assignment 6 External Power supply and signals connection 6 Additional FRnet signal connectors 6 I O connectors 7 3 3 Interface Circuit 8 3 4 Address Group number Setting 9 3 5 C...

Страница 3: ...en do not feel that they are using remote IO modules The FRnet input modules can connect with the FRnet output modules through the twisted 2 wire bus without a CPU module to become a MagicWire applica...

Страница 4: ...x switching voltage 125Vdc 270Vac Max switching current 5A 100 000 operations min at full load Life expectancy 20 000 000 operations min at no load Release time 5 ms Control logic TTL low Relay on Pow...

Страница 5: ...of FR 32R Connectors for FRnet quick connection Group number setting JP2 CH17 CH32 External Power and FRnet wiring interface Speed and Hold state setting JP9 Termination resistor setting CH1 CH16 7 4...

Страница 6: ...ction J1 Additional FRnet signal connectors All FRnet A signals are internally connected together and all FRnet B signals are connected together too Following two connectors are used for FRnet quick c...

Страница 7: ...7 I O connectors CN1 CN2 The CMnn and NOnn in these figures represent the COM and the N O pins of channel nn respectively 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 8: ...8 3 3 Interface Circuit 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 9: ...S5 and S6 are used for 128 group system Although the settings for 128 group system are omitted here they are similar to other jumpers that construct a binary code for address RA0 RA1 RA8 RA9 RA2 RA3...

Страница 10: ...es are listed in the following table The standard speed 250K bps is set by having a jumper at CK0 position In the following table the jumper at HOLD position determines what kind of the output status...

Страница 11: ...rmination resistor LED Each LED indicator has a label expressing its function Note that the Communication Run LED and the Error LED indicate the quality of the communication When FRnet is running norm...

Отзывы: