background image

 

FR-32R Modules 

 

User’s Manual 

 
 
 
 
 
 

Warranty 

All products manufactured by ICP DAS are warranted 

against defective materials for a period of one year from 
the date of delivery to the original purchaser. 

 

Warning 

ICPDAS assumes no liability for damages consequent 

to the use of this product. ICP DAS reserves the right to 
change this manual at any time without notice. The 
information furnished by ICP DAS is believed to be 
accurate and reliable. However, no responsibility is 
assumed by ICP DAS for its use, not for any infringements 
of patents or other rights of third parties resulting from its 
use. 

 

Copyright 

Copyright 2006 by ICP DAS. All rights are reserved. 
 

Trademark 

The names used for identification only may be 
registered trademarks of their respective companies.

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Содержание FR-32R

Страница 1: ...he right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not f...

Страница 2: ...e of FR 32R 5 3 2 Pin Assignment 6 External Power supply and signals connection 6 Additional FRnet signal connectors 6 I O connectors 7 3 3 Interface Circuit 8 3 4 Address Group number Setting 9 3 5 C...

Страница 3: ...en do not feel that they are using remote IO modules The FRnet input modules can connect with the FRnet output modules through the twisted 2 wire bus without a CPU module to become a MagicWire applica...

Страница 4: ...x switching voltage 125Vdc 270Vac Max switching current 5A 100 000 operations min at full load Life expectancy 20 000 000 operations min at no load Release time 5 ms Control logic TTL low Relay on Pow...

Страница 5: ...of FR 32R Connectors for FRnet quick connection Group number setting JP2 CH17 CH32 External Power and FRnet wiring interface Speed and Hold state setting JP9 Termination resistor setting CH1 CH16 7 4...

Страница 6: ...ction J1 Additional FRnet signal connectors All FRnet A signals are internally connected together and all FRnet B signals are connected together too Following two connectors are used for FRnet quick c...

Страница 7: ...7 I O connectors CN1 CN2 The CMnn and NOnn in these figures represent the COM and the N O pins of channel nn respectively 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 8: ...8 3 3 Interface Circuit 7 495 109 02 08 sales bbrc ru www bbrc ru...

Страница 9: ...S5 and S6 are used for 128 group system Although the settings for 128 group system are omitted here they are similar to other jumpers that construct a binary code for address RA0 RA1 RA8 RA9 RA2 RA3...

Страница 10: ...es are listed in the following table The standard speed 250K bps is set by having a jumper at CK0 position In the following table the jumper at HOLD position determines what kind of the output status...

Страница 11: ...rmination resistor LED Each LED indicator has a label expressing its function Note that the Communication Run LED and the Error LED indicate the quality of the communication When FRnet is running norm...

Отзывы: