Technical support: 

[email protected]

                                                    P5 

 

4  

Modbus Address 

The nDO parameters in the following Modbus Address Tables are as follows: 

Mode 

Name 

Universal 

DIO 

Number of DO channels 

(nDO) 

Number of DI channels 

(nDI) 

ET-2268 

 
 

 

(0xxxx) DO address:

 

Begin 

address 

Points 

Description 

Bits 

Per 

Point 

Range 

Access 

Type 

0 (0x0) 

1~nDO 

Digital Output Channels 

0: OFF, 1: ON 

R/W 

100 (0x64) 

1~nDO 

Enables  the  PWM  for  all 
DO Channels 

0 = Off 
1 = On 

(Default= 0) 

R/W 

127 (0x7F) 

Restores all default web 

settings

 

1 = Restore 

128 (0x80) 

Default ID Settings

 

1 = Restore 

133 (0x85) 

Reboots the ET-2200 

module

 

1 = Restore 

.

 

235 (0xEB) 

1~nDO 

Sets the Power-on value for 

all DO Channels 

0: OFF, 1: ON 

(Default: 0) 

R/W/F 

267 (0x10B)  1~nDO 

Sets the Safe value for all DO 

Channels 

0: OFF, 1: ON 

(Default: 0) 

R/W/F 

R

”: Read, “

W

”: Write, “

F

”: Settings are recorded in flash by default,   

E

”: After writing DO[60] register, the data will be stored in flash.

 

 

 

Note 

For detail “DI/DO Modbus Address” information, refer to Section 6.3 Modbus Register Table

 

of user’s manual (

http://ftp.icpdas.com/pub/cd/6000cd/napdos/et2200/document/

).

 

 

 

 

Содержание ET-2200 Series

Страница 1: ...68 Quick Start v1 1 Mar 2018 What s in the box Related Information The package includes the following items ET 2268 Module x 1 Quick Start x1 This Document ET 2200 Series Product Page Documentation Fi...

Страница 2: ...your Windows firewall and Anti Virus firewall first else the Search Servers on Chapter 5 may not work Please contact with your system Administrator 2 Connect both the ET 2268 and your PC to the same...

Страница 3: ...ts Wiring Note Pin Assignments Wire Connections Readback as 1 Readback as 0 Relay Output Form A Relay in NO1 NO3 NO5 NO7 Form C Relay in NO0 NO2 NO4 NO6 NCx COMx NOx AC DC Load1 Load2 NOx COMx Load AC...

Страница 4: ...g the DI and DO for Self test A tip for connecting the wire to the connector A tip for removing the wire from the connector 1 Connect the External Power 24V to the NO0 pin Pin01 2 Connect the External...

Страница 5: ...0 R W 127 0x7F 1 Restores all default web settings 1 1 Restore W 128 0x80 1 Default ID Settings 1 1 Restore W 133 0x85 1 Reboots the ET 2200 module 1 1 Restore W 235 0xEB 1 nDO Sets the Power on value...

Страница 6: ...Search Servers to search your ET 2268 3 Double click your ET 2268 to configure the settings Factory Default Settings of ET 2268 IP Address 192 168 255 1 Subnet Mask 255 255 0 0 Gateway 192 168 0 1 4...

Страница 7: ...the ET 2268 is working well with new configuration 2 Click the name of ET 2268 to select it 3 Click the Web button to log in to the web configuration pages Or enter the URL address of the ET 2268 in t...

Страница 8: ...om P8 5 In the Home page allows a simple test to be performed to verify the Digital Input and Output functionality 6 In the Digital I O section click the DO0 button to ON Red 7 Verify that the output...

Отзывы: