The 

“Power  On  Value”

“Safe  Value” 

and 

“Safe  Delay”

  for  digital  output  can  be  set 

without rebooting the module. 

 

 

 

 

6.

 

If  the  network  settings  have  been  changed,  please  click  the 

“Update  Network  Settings”

 

button to update the configuration and reboot the module.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

7.

 

Configuration settings of EIP-2000 

Network Settings 

Item 

Settings (default) 

IP

 

192.168.255.1 

Gateway 

192.168.0.1 

Mask 

255.255.0.0 

For configuration of the 

Address Type

Static IP Address

Subnet Mask

 and 

Default Gateway

 of the EIP-2000. Please refer 

to section “

4.2.1 Network Settings

” 

 
 

LED Indicator 

LED 

LED Status 

Description 

Power LED 

Always On 

Module is in Run mode. 

Flashing 

Module is in Init mode. 

Status LED 

Always On 

EtherNet/IP connection is failed. 

Blink per second 

EtherNet/IP connection is successful. 

Blink per 300 ms 

EtherNet/IP disconnected during communication but still in Safe-
Delay time. 

Blink per 100 ms 

Module is about to reboot. 

I/O status LED 

On 

The DI/DO is activated. 

Off 

The DI/DO is inactivated. 

For configuration of the 

Power On Value

Safe Value

Safe Delay

 for the EIP-2000. Please refer to section “

4.2.2 Digital 

Settings

” 

 

 

 
 
 
 

Содержание EIP-2060

Страница 1: ...ckage includes the following items Install EIP 2000 Utility The software is located at Fieldbus_CD EtherNetIP remote io EIP 2060 Utility Quick Start Guide This Document For EIP 2000 Series English Jan...

Страница 2: ...ll and anti virus firewall first else the Network Scan on step 4 may not work Please contact with your system Administrator 3 Check FW OP DIP switch if it is on OP position 4 Connect both the EIP 2000...

Страница 3: ...I O Wire Connection 20 pin Spring type terminal connector Pin Description Pin Description 1 R5_COM 2 R4_COM 3 R5_ON 4 R4_ON 5 DI COM 6 R3_COM 7 DI5 8 R3_ON 9 DI4 10 R2_COM 11 DI3 12 R2_ON 13 DI2 14 R1...

Страница 4: ...2000 modules 3 Click the EIP 2060 or other EIP 2000 modules on the device list below to open the configuration dialog of EIP 2000 Each EIP 2000 module has its own configuration interface 4 Test the d...

Страница 5: ...ddress Subnet Mask and Default Gateway of the EIP 2000 Please refer to section 4 2 1 Network Settings LED Indicator LED LED Status Description Power LED Always On Module is in Run mode Flashing Module...

Страница 6: ...art Guide 1 Open RSLogix 5000 and create a new project Figure5 1 Create a new project 2 Select the PLC type and give the project a name Figure5 2 Set the PLC type and project name 5How to connect with...

Страница 7: ...060 Quick Start Guide 3 Create a new module in the Ethernet item Figure 5 3 Create a new module 4 Select the ETHERNET MODULE below Communications in the Select Module window Figure5 4 Select ETHERNET...

Страница 8: ...ings of EIP 2060 module Table 5 1 Data Assembly of EIP 2060 Data Assembly Byte count Description Input Assembly 26 1st Byte DI status 2nd Byte DO status read back 3rd 26th Byte DI counters Output Asse...

Отзывы: