7.4 Save Configuration Data to Memory
In this section the procedure of saving encoder configuration parameters to the non-
volatile memory of the ECAT-2092T is being discussed.
The CoE objects 0x8000 to 0x8010 contains all the parameters needed to configure the
ECAT-2092T. TwinCAT allows the user to set the configuration parameters via the System
Manager (Figure 33) or from a TwinCAT PLC via ADS (TcEtherCAT.lib library).
If the CoE parameters of the ECAT-2092T are set online, then the device does not
automatically store the data to its non-volatile memory, and therefore the data will be
lost once the device is switched off. The 0xF008 object provides functions to store the
configuration data permanently to the non-volatile memory of the ECAT-2092T and the
setting will be immediately available immediately after a restart.