CAN-2054D
User’s Manual (v1.10, April/2015)
14
3.3 Connection Object (Class ID:0x05)
This section presents the externally visible characteristics of the
Connection Objects associated with the Predefined Master/Slave Connection
Set within slave devices.
The default IO connection path is as follow.
Connection Path
Class ID
Instance ID
Attribute ID
Poll Produced
0x04
0x64
0x03
Poll Consumed
0x04
0x65
0x03
Bit Strobe Produced
0x04
0x64
0x03
Bit Strobe Consumed
0x04
0x65
0x03
Connection
Instance ID
Description
1
References the Explicit Messaging Connection into the Server
2
References the Poll I/O Connection
3
References the Bit
–Strobe I/O Connection
Содержание CAN-2054D
Страница 6: ...CAN 2054D User s Manual v1 10 April 2015 6 2 Hardware 2 1 Structure Top View Bottom View...
Страница 10: ...CAN 2054D User s Manual v1 10 April 2015 10 2 4 PIN Assignment...
Страница 11: ...CAN 2054D User s Manual v1 10 April 2015 11 2 5 Wire Connection...
Страница 21: ...CAN 2054D User s Manual v1 10 April 2015 21 Appendix A Dimension...