ALM-06-WF User’s Manual
ALM-06-WF
User’s Manual (Rev1.0, Feb./2019) ------------- 20
3.3
Alarm Mode & Audio Editor
ALM-06-WF contain 8 kinds of alarm mode,
Mode 0 ~ 3
are DI1~DI6 in single
independence channel trigger, in DIx channel priority, the priority of DI channel is
DI6 > DI5... > DI1.
Mode 4 ~ 7
are DI1~DI5 in Binary trigger & DI6 in single channel trigger, the
priority of DI channel in this mode is DI6 > 11111b(0x1F)>…> 00001b(0x01).
Alarm Mode
Mode
Channel Trigger Function
Mode
Binary Trigger Function
0
General Playback
4
General Playback
1
Trigger Input
priority
Playback
5
Trigger Input priority Playback
2
Hold Repeat Playback
6
Hold Repeat Playback
3
Memory Once Playback
7
Memory Once Playback
Max 4 MP3 files
can be add for each Channel or Binary trigger alarm, it will
playback from #1 to #4 for the trigger depend on the setting.
Relay output
can set an extend alarm output to trigger other device.
All those setting can be done in PC Utility & can be monitor Armed/DisArmed
on both PC Utility or Android APP, show as below.
Figure 3-3
:
ALM-06-WF PC Utility Audio Editor page.