Firmware Update via 7188XW.exe (Ver. 1.1/Aug. 2018)

 

 

Page:

 1

 

 

1.

 

Setting up the PDS-700 

 

Before updating the firmware, please ensure that the PDS-700 module is connected with your host 
computer. Refer to the following steps for the details. 

 

Step 1: 

Switch off 

the Power to the PDS-700 module. 

Step 2: Connect the DB-9 connector of CA-0910 download cable to your host computer. 

Step 3: Wire the CA-0910 to PDS-700 module, as follows: 

 

 

 

 

 

3-1: Connect the 

CA-0910.TX

 with 

PDS.700.TxD1

   

3-2: Connect the 

CA-0910.RX

 with 

PDS.700.RxD1

   

3-3: Connect the 

CA-0910.GND

 with 

PDS.700.GND

 

 

 

Vs+ 

 

GND 

Содержание PDS-700 Series

Страница 1: ...es the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use n...

Страница 2: ...puter Refer to the following steps for the details Step 1 Switch off the Power to the PDS 700 module Step 2 Connect the DB 9 connector of CA 0910 download cable to your host computer Step 3 Wire the C...

Страница 3: ...te via 7188XW exe Ver 1 1 Aug 2018 Page 2 Step 4 Short the INIT and GND pins of the PDS 700 module in Init to initiate the update Step 5 Switch on the Power to the PDS 700 module GND Short INIT and GN...

Страница 4: ...p format You can decompress the zip file by 7 Zip WinZip WinRAR utilities Step 2 Modify COM Port number in 7188xw ini file depend on your PC COM Port that connect to PDS 700 For Example first paramete...

Страница 5: ...e 8 for more details e g PDS 755 bat Step 4 You are now ready to update the firmware The PDS 7xx bat file will auto run the 7188XW exe utility program and shows the progress of the update Step 5 The 7...

Страница 6: ...ly End file xxx message Then click the X icon on the right top corner of the windows to close it Step 7 Disconnect the INIT and GND pins of DS 700 module Step 8 Switch off the Power to the PDS 700 mod...

Страница 7: ...n your Host PC and then run the Utility to search for any PDS 700 module connected to the nework Download the VxComm Utility Step 11 Configure the correct network settings for the required PDS 700 mod...

Страница 8: ...1 1 Aug 2018 Page 7 Step 12 Click the name of the PDS 700 module Step 13 Click the Web button Step 14 Log in to the web configuration pages for the PDS 700 Step 15 Verify that the firmware version and...

Страница 9: ...back Note 2 Make sure the 7188XW exe and autoexec bat program files exist on the same folder If not update firmware can t be successful back Note 3 If the IP address settings do not work correctly e...