PPC-090T-APL User’s Manual
IUMPPC090TAPL-01 Ver.1.0A Aug, 2019
11
1.5.2 Panel Mounting
PPC-090T-APL series support clamp mount kit, which includes 4pcs of clamp and
screw in a bag of the package box. User can follow the instruction to do the panel
mount as below.
1. Please refer the Section 1.4 to make a cutout hole on your mechanical or frame.
Please note that there is thickness limitation of the mounting wall for
clamp mount installation. The suggestion of mounting wall thickness
limitation is 20 mm.
2. It has 4pcs of clamp and screw, and each clamp and screw is paired. Screws
4pcs of clamp and screw together respectively.
3. Place PPC in a cutout mechanical or frame, which mounts the panel to align the
bottom of the panel housing with the bottom edge of the cutout. This way can
help hold the panel steadily.
4. At the back side of the mounting wall, insert the clamp into the slide hole at the
side bracket on the panel. Fit the screw on the clamp and screw on both of
clamp and mounting wall. Please be careful and make sure that 6 clamps and
screws have been lock tightly.