Software Not Loading
If the software doesn’t load for any reason, we recommend
turning the unit OFF and ON first to see if that solves the issue.
If the issue persists, please contact iCool Support.
Remote Screen Not Connecting
Make sure that the data cable is correctly plugged to the
screen and to the Electronics Box. You can also try turning
the unit OFF and ON again and waiting for 30 seconds. The
connection should be automatic.
Safety Switch Tripping
If your unit is tripping the safety switch, please make sure it is
connected to the correct voltage noted in the documentation
that came with the machine. As with any device, operating on
the wrong voltage can do a lot of damage.
If either the Turbo’s safety switch or the fuse device on the
building’s switchboard that supplies the Turbo trips, it is
essential that an electrician determines the reason for this
before restarting the system. It could mean a dangerous
situation has occurred.
These safety device protect against both current over load and
leakage to ground.
Current overload is when the system draws much more power
than normally needed which could indicate a motor failure.
Earth leakage trips occur when the power running in the
active power line supplying the machine is not equal to
power returning in the neutral line from, indicating that
some electricity is being lost somewhere. Such safety devices
anticipate this could mean that a person is receiving an
electric shock and they are designed to cut off the electric
power instantly if even a tiny miss match is detected. (30mA)
Often they operate so fast that the person will not even feel
the electric shock. These devices known as RCDs save many
lives.
Condensation
Please note that your unit is a very powerful chiller and
condensation will occur inside of it. Water may leak at the
back of the chiller, this is completely normal. If necessary, you
can place a dripping tray under the unit to catch the overflow
water.
Screen Freeze
This is a very rare issue. If the screen freezes while the iCool
is running normally, the main computer will usually still carry
on running the system and monitoring the safety features
but you will not be able to change anything and the displayed
temperatures will not update. You can either allow it to keep
running if that is more convenient, or you can restore the
system to normal operation by switching off the main power
and re starting again.
Manual Override Operation
In the rare event that the touch screen fails to connect or fails
to turn on for any reason you can still operate your Turbo with
the built in temporary over ride feature.
There is a small press button inside the lifting handle on the
side of the Turbo with the smoked glass screen covering the
electronics box.
If you press and hold this button for more than 10 seconds
the Turbo will start normally and begin cooling (or heating) at
the last temperature that you set which is always stored in the
system memory.
All functions will operate normally as will all safety features,
but you will not be able to change the temperature or to read
the temperatures.
This function is provided so that you can still use your machine
while a touch screen problem is being resolved.
Содержание 5 Series
Страница 1: ...Series 5 Owner s Manual Turbo Range www icoolsport com support icoolsport com ...
Страница 2: ......
Страница 4: ...Your Turbo O1 ...
Страница 10: ...Quick Setup O2 ...
Страница 22: ...Get Started O3 ...
Страница 28: ...SafetyProcedures O4 ...
Страница 32: ...TechnicalSupport O5 ...
Страница 33: ......
Страница 40: ......