background image

13

2

5

1. Connect MAIN  POWER

Plug the power cable to the Main Power socket                and 

to a 3-pin earthed wall socket rated at least 13 Amps at 220 

volts (and 26 Amps at 110 volts if your machine is 110V). Please 

avoid the use of long extension cords as they may result in 

voltage drops that may trigger the inbuilt safety system.

MiPods must be connected to the voltage marked on the 

machine, 

 /!\ they are NOT multi-voltage and using a 

different voltage may cause severe damage

.  The power 

input socket on the side of your MiPod must be connected to 

standard AC power capable of providing at least 13 Amps in 

countries with a 220v supply, and 26 Amps in countries with a 

110v supply. The system requires much less power than this for 

normal operation, however they need more power for up to a 

minute each time they start up and this must be allowed for. A 

3 pin grounded power outlet is absolutely mandatory for user 

safety. Never use a 2 pin plug it could be dangerous. Your MiPod 

is fitted with an electrical safety device to protect users and All 

AC power connections used must have an earth connection 

that complies with your local electrical safety regulations. 

2. Connect DATA CABLE

Plug the 

blue

 DATA cable to the 

Ethernet Port            on the machine and 
to the RJ45 socket on the back of 
your screen. Please note, a power 
cable is not required for the screen. 
The screen will receive its power 
from the

 blue

 DATA cable (supplied).

Mount the screen on a wall or anywhere you want using the 
wall mount bracket kit (included). Please note the DATA cable 
supplied is 5m long. 

3. Turn  on SWITCH

Turn the Main Power Switch ON              and check that the 

screen turns on correctly. If that is the case, a WELCOME PAGE 

will appear on the touch screen.   

RJ45

OTG

DC

Blue DATA cable Power cable

SCREEN NOT CONNECTING

If the screen does not light up when turning ON the 

switch of the MiPod, please make sure that:

1

  The Main power cable is correctly connected to the 

power socket on the unit and to the wall and that no 

extension cables are being used. 

2

  The Safety Switch is in the ON or UP position.  

Please note that if your MiPod ever detects a potential 

electrical safety risk, this switch will instantly turn off all 

electric power to your MiPod. Always have an electrician 

inspect your MiPod for safety should this ever happen 

and before turning it back on.

3

  The Data cable is correctly connected to the 

Ethernet socket on the unit and on the screen.

Please note: when contacting iCool Support, please 

send pictures and a short video of the screen and pool 

set up. This will help engineers to better determine the 

problem and give you the best advice.

This is how you final set up should look:

Components comply with

Compact

Series 4
Made in Australia

IC22000

On

Off

1

Содержание 2 Series

Страница 1: ...Series 2 Owner s Manual MiPod Range www icoolsport com support icoolsport com ...

Страница 2: ......

Страница 3: ...O1 Your MiPod O2 Quick Set Up O3 Get Started O4 Safety Procedures O5 Technical Support Table of contents ...

Страница 4: ...Your MiPod O1 ...

Страница 5: ...eir own being the most technically advanced and the most powerful chilling systems of any comparable product available on the market They give you the fastest chilling performance available anywhere Manufactured from the highest quality materials and components for long service life ice bath sessions are quick to set up and easy to use What s new in Series 2 Wide Range Our large range offers fully...

Страница 6: ...n the voltage sticker is located inside the Electronic box right below the Main Switch Included with your MiPod This manual is intended to help you get started using the MiPod Range of all in one products To know your device s features specifications and operation instructions you will first need to identify your product Below are some guidelines to help you determine your model your series and yo...

Страница 7: ...ls Control Weight MiPod Chill 220V AC Single phase 50 60Hz 5000W 2000W 350g Hychill Minus 40 15 Amp 30mA 3 Pin heavy duty with Earth Pool Grade GRP Marine Grade Alumnium Remote 13inch Touch Screen 90Kg Empty MiPod Series with Internal Heat Pump support icoolsport com Made in Australia FrontView Left SideView Right SideView Componentscomplywith Compact Series4 MadeinAustralia IC22000 On Off 6 1 7 6...

Страница 8: ...om 25ºC down to 5ºC Please note the time taken each time depends on many variables the amount of water the surrounding room temperature the ventilation of your machine the initial water temperature Leave the unit Always On so you can enjoy an ice bath anytime you want ...

Страница 9: ...can be connected to any unit from our Portable chillers range Must be ordered at the same time as custom water connections are pre fitted in the factory Installation recommended to be completed by a certified plumber ...

Страница 10: ...Quick Setup O2 ...

Страница 11: ...ed that you seek the advice of a qualified engineer or the local council if unsure If eventual servicing is required for any particular reasons please also make sure that you have easy access to all side vents and panels We suggest that you closely consider the required location for your ice bath prior to filling your bath Please account for the attachment point to drain the surplus water We also ...

Страница 12: ...ur MiPod machine to the wrong voltage or this will cause serious damage not covered under warranty MiPod Chill Hot Dual Temp Componentscomplywith Compact Series4 MadeinAustralia IC22000 On Off 3 1 2 5 6 4 Electronic Panel Box 1 Main Power Switch 7 6 Override Button 5 Ethernet Port for DATAcable 3 Serial Number Label 2 Main Power Socket 4 Safety Test Button 220V 7 Voltage 5 ...

Страница 13: ...n the back of your screen Please note a power cable is not required for the screen The screen will receive its power from the blue DATA cable supplied Mount the screen on a wall or anywhere you want using the wall mount bracket kit included Please note the DATA cable supplied is 5m long 3 Turn on SWITCH Turn the Main Power Switch ON and check that the screen turns on correctly If that is the case ...

Страница 14: ...re fitted as it must be custom made once on site Your compact will come with PVC barrel unions suited for 1 inch PVC pipes PVC pipes MiPod water outlets are not included Installation is recommended to be completed by a certified plumber Insulation of the pipes is a must for the full length of the two water pipes otherwise a lot of cold energy will be lost Remote Screen Optional With MiPod Remote v...

Страница 15: ...Davey Cartridge Filter additional water outlets are manufactured on the shell of your MiPod when ordered at the same time This must be ordered in advance and cannot be retro fitted The connecting PVC pipes between the filter and the MiPod are not included Installation is recommended to be completed by a certified plumber Insulation of the pipes is a must for the full length of the two water pipes ...

Страница 16: ...with a hose A permanent water connection is not required Simply fill with a hose over the Mipod to at least cover the internal top water outlet If this is not followed the machine will draw air and cause the safety system to shut the system down To empty water from MiPod simply connect a 12mm hose to the drain valve and OPEN valve to let water go Drain Valve Make sure the drain valve is in the CLO...

Страница 17: ...17 Recommended water level ...

Страница 18: ...Get Started O3 ...

Страница 19: ......

Страница 20: ...perating Screen will appear 3 Initial Connection Your touch screen will usually connect to the MiPod main operating page automatically however in some circumstances this page may appear because it has not yet recognized your MiPod If this happens after a short time a small blue square appears at the top left of the screen as shown below Simply tap anywhere on this small blue square to connect manu...

Страница 21: ... of continuous 24 7 operation If you wish to have your pool available at your desired temperature at any time of the day or night then you can leave it running continuously at very low operating cost The MiPod is so efficient that if you use it every day it will cost less to operate if you leave it running continuously A sophisticated power management system is included that will automatically use...

Страница 22: ...t by clicking on the Menu Button and selecting SETTINGS Temperature Unit You can switch between Centigrade or Fahrenheit Light Dark mode You can change the display mode of your screen from Light to Dark mode Volume You can change the volume of the system sounds by clicking repeatedly or Energy Saving You can set different levels of energy saving Level 1 provides full cooling power Level 5 saves th...

Страница 23: ...ime and do the same to set a Change Over Time in between sessions then click SAVE LOCK You can also lock your screen by entering a 4 digit passcode This will limit the access to the settings of the chiller To set a passcode go to MENU LOCK Set a PIN and enter a combination of 4 numbers You can remove this settings by selecting Remove PIN INFO All information about your machine is available in Menu...

Страница 24: ...SafetyProcedures O4 ...

Страница 25: ... button is located on the Main Power Switch ELECTRIC SHOCK PROTECTION LIMITATIONS All iCool machines have built in electrical safety residual earth leakage protection systems It can only protect against devices actually connected to the iCool including the water pump It can not protect against faults in other unrelated electric devices in the area All electric devices in any pool area must only be...

Страница 26: ... pump especially designed for the purpose The pumps we provide are resistant to chlorine and salt water at normal concentrations but the use of chemicals should be kept within the range normally recommended for swimming pools to prolong the life of the pump and the titanium heat exchanger tanks inside the cooling unit Never use bromide as it is highly corrosive to all materials and can cause irrit...

Страница 27: ... to freeze in the MiPod or its machinery If extreme cold conditions are expected empty the water from the unit If not being used do not allow the internal tank to freeze solid Either empty the water or add salt or anti freeze to lower the temperature at which the water freezes If not in use drain the unit and store at ambient temperature Operation in Very Hot Weather iCool machines are very powerf...

Страница 28: ...TechnicalSupport O5 ...

Страница 29: ......

Страница 30: ...ion is lack of water flow It can occur if air is trapped in the water pipes or in the pump or if flow is restricted by some sort of blockage it could be hair dust or any other debris The machine will attempt to clear it automatically several times by surging the pump to dislodge air If after several attempts it cannot correct the lack of water flow it will shut the machine down and warn you that a...

Страница 31: ... the temperature below about 7ºC or 45ºF it is occasionally possible in certain climatic conditions for the heat exchange tanks to freeze solid This will block most or all the flow of water It should be understood that in order to cool the pool water to these extremely low temperatures the system must cool to at least 5ºC below the set temperature to allow for losses and this takes it very close t...

Страница 32: ...ected temperature If your MiPod is not cooling or heating at all but seems to be running correctly it may most likely be out of refrigeration gas and needs to be re gassed Re gassing can be done by your local refrigeration technician Once re gassed you must absolutely provide enough ventilation to keep the machine within a safe operating temperature System Too Hot Warning Your MiPod can move large...

Страница 33: ...it OFF and ON again and waiting for 30 seconds The connection should be automatic Software Not Loading If the software doesn t load for any reason we recommend turning the unit OFF and ON first to see if that solves the issue If the issue persists please contact iCool Support Condensation Please note that your unit is a very powerful chiller and condensation will occur inside of it Water may be vi...

Страница 34: ...product fault is covered by our Standard One Year Warranty please check the Product Warranty Statement available on our website iCoolsport may offer assistance via email to fix your issue recommend a local repair service or ask for the unit to be shipped back for repair Any repair does not extend the warranty period Local Repair All local repairs must be approved in writing by iCool and if your un...

Страница 35: ...est your package will be the more expensive it will be to ship amake sure to pack it as small as possible International returns your freight company may ask for the value of the item to send it to Australia To avoid having to pay duties again on your product we recommend setting it to a maximum of 100 and making sure to note that it is being returned for REPAIR only and that will be re exported fo...

Страница 36: ......

Отзывы: