13
2
5
1. Connect MAIN POWER
Plug the power cable to the Main Power socket and
to a 3-pin earthed wall socket rated at least 13 Amps at 220
volts (and 26 Amps at 110 volts if your machine is 110V). Please
avoid the use of long extension cords as they may result in
voltage drops that may trigger the inbuilt safety system.
MiPods must be connected to the voltage marked on the
machine,
/!\ they are NOT multi-voltage and using a
different voltage may cause severe damage
. The power
input socket on the side of your MiPod must be connected to
standard AC power capable of providing at least 13 Amps in
countries with a 220v supply, and 26 Amps in countries with a
110v supply. The system requires much less power than this for
normal operation, however they need more power for up to a
minute each time they start up and this must be allowed for. A
3 pin grounded power outlet is absolutely mandatory for user
safety. Never use a 2 pin plug it could be dangerous. Your MiPod
is fitted with an electrical safety device to protect users and All
AC power connections used must have an earth connection
that complies with your local electrical safety regulations.
2. Connect DATA CABLE
Plug the
blue
DATA cable to the
Ethernet Port on the machine and
to the RJ45 socket on the back of
your screen. Please note, a power
cable is not required for the screen.
The screen will receive its power
from the
blue
DATA cable (supplied).
Mount the screen on a wall or anywhere you want using the
wall mount bracket kit (included). Please note the DATA cable
supplied is 5m long.
3. Turn on SWITCH
Turn the Main Power Switch ON and check that the
screen turns on correctly. If that is the case, a WELCOME PAGE
will appear on the touch screen.
RJ45
OTG
DC
Blue DATA cable Power cable
SCREEN NOT CONNECTING
If the screen does not light up when turning ON the
switch of the MiPod, please make sure that:
1
The Main power cable is correctly connected to the
power socket on the unit and to the wall and that no
extension cables are being used.
2
The Safety Switch is in the ON or UP position.
Please note that if your MiPod ever detects a potential
electrical safety risk, this switch will instantly turn off all
electric power to your MiPod. Always have an electrician
inspect your MiPod for safety should this ever happen
and before turning it back on.
3
The Data cable is correctly connected to the
Ethernet socket on the unit and on the screen.
Please note: when contacting iCool Support, please
send pictures and a short video of the screen and pool
set up. This will help engineers to better determine the
problem and give you the best advice.
This is how you final set up should look:
Components comply with
Compact
Series 4
Made in Australia
IC22000
On
Off
1
Содержание 2 Series
Страница 1: ...Series 2 Owner s Manual MiPod Range www icoolsport com support icoolsport com ...
Страница 2: ......
Страница 4: ...Your MiPod O1 ...
Страница 10: ...Quick Setup O2 ...
Страница 17: ...17 Recommended water level ...
Страница 18: ...Get Started O3 ...
Страница 19: ......
Страница 24: ...SafetyProcedures O4 ...
Страница 28: ...TechnicalSupport O5 ...
Страница 29: ......
Страница 36: ......