STEP 3

STEP 4

Connect the plug from the filter pumps to the 

socket on the rear panel of the iCool Twin

Check that all connections are to the correct side of the iCool Twin

If you are operating 2 pools make sure that both the hoses and the 

filter pump’s power cable for each pool are connected to the same side 

of the iCool Twin. Connect the LEFT side pool’s hoses and filter pump 

power cable to the to the LEFT side of the iCool and the RIGHT side 

pool’s hoses and filter pump power cable to the RIGHT side of the iCool, 

looking from the back.

Connect Electric Power

Connect the power cable supplied with your iCool to a standard power 
outlet capable of providing at least 12 amps in countries with a 220 
V supply and 24 amps in countries with a 110 V supply. Although the 
system requires much less power than this during normal operation, 
all heat pump compressor motors need considerably more power for a 
minute or so each time they starts up.

Your System Software will begin loading

Your iCool TWIN has a TWO full colour high-resolution touch screens 
that eliminate all switches and provide complete control over all of your 

iCool’s systems in a user-friendly and intuitive manner. 

It also provides a substantial amount of additional information to assist 

you. When you turn on the power for the first time the system will load 

the latest software from its memory and run a diagnostic self test 
routine. This will take about 20 seconds. During this time you will see 
this screen (shown at right) and then a BLACK screen.

The System Status Bars will flash white 

The STATUS BARS on each side at the front of the iCool Twin will change 
colour or flash to give a clear indication of each function. The left one is 
for the left side heat pump and the right side for the right hand heat pump.

Main Power Switch

The main power switch is also part of the ELECTRICAL SAFETY CIRCUIT that guards against the possibility of electric shock. Every electric 
component in the iCool is protected by this device. It is a good idea to test this system each time you use the iCool by turning on the main switch 
and then pressing the test button above the switch. If the safety system is working normally, pressing the test button will cause the main power 
switch to shut down instantly. 

Reset the main switch to ON to begin normal operation. If it does not shut down instantly when you touch the test button do not use the iCool 
until the fault is found and corrected by a trained person.

WARNING

For safety, the power outlet you use must be earthed correctly

The Software Loading Screen

Pool 2

Pool 1

Содержание TWIN

Страница 1: ...Owners Manual iCool TWIN ...

Страница 2: ...olled heating Now you can provide advanced contrast therapy sessions at a much lower cost The Twin can provide any temperature used in recovery therapy into 2 pools at the same time One can be hot and one cold or both cold and all temperatures are accurately and automatically maintained The TWIN is the perfect solution for a world class recovery centre at an affordable price in fact the lowest pri...

Страница 3: ...ugh your iCool is produced by a high quality long life circulating pump that includes an effective filter system to keep the pool water clean The pump with your iCool can not begin to operate correctly unless it is fed with a head of water from a pool therefore the level of water in the pool must be higher than the pump and any air tapped in the feeding hoses must be removed There must be no air t...

Страница 4: ...in 4 3 Connect 5 to the bottom of the pool 2 To operate 2 pools simply repeat the illustration for the second pool STEP 1 2 QUICK START GUIDE The following is a quick start guide to get your iCool up and running quickly however you should read the entire manual to get the most out of your iCool WARNING The water level in the pool must be above the water inlet of the pump or the pump can not start ...

Страница 5: ...anner It also provides a substantial amount of additional information to assist you When you turn on the power for the first time the system will load the latest software from its memory and run a diagnostic self test routine This will take about 20 seconds During this time you will see this screen shown at right and then a BLACK screen The System Status Bars will flash white The STATUS BARS on ea...

Страница 6: ...r iCool is ready to use The Status bars glow BLUE when only the pump is running GREEN when the cooling system is running and RED when the heating system is running If the bars glow RED when you try to start cooling please refer to page 7 for an explanation Your twin is actually 2 separate iCool machines so they can be operated completely independently from each other If you only want to use one sy...

Страница 7: ...mperature you require up to 45ºC or 108ºF and then touch the START button This takes you back to the main operating screen where you can now start the PUMP and the SYSTEM as usual The status bar on the front of the unit will turn RED when you touch the START button to indicate that your iCool is now heating It will continue to heat until it reaches your pre set temperature and then hold that tempe...

Страница 8: ...fety reasons you cannot change directly from heating to cooling or cooling to heating To do this you must switch off the entire system at the main switch and start again This is required to prevent the system from changing modes accidentally See setting up heating mode on page 8 Fan Speeds During normal operation the main fan may automatically change speeds as required to maintain the highest effi...

Страница 9: ...se this feature The three settings you can change are the fan speed range the temperature from degrees Centigrade to Fahrenheit and the sound level from the screen Cooling Fan Speed This allows you to set the main cooling fan to either NORMAL or QUIET MODE Generally you should always leave it in the NORMAL mode which is fully automatic and allows the system to control the fan speed to give the ver...

Страница 10: ...t mode Temperature Limitations Because of the dangers of hypothermia in the case of an unattended athlete using the pool your system will not allow you to set temperatures below 5 C 40 F If the model you are using is the contrast model which also provides heating for contrast therapy you cannot set the temperature above 45 C 112 F because of the risk of scalding These temperature limits have been ...

Страница 11: ...eeze due to data or software conflicts Your iCool has 2 computers that monitor and communicate with each other Occasionally a data error can cause them to stop communicating We have designed the system to be as fail safe as possible In most cases if the screen freezes the main computer will still carry on running the system and monitoring the safety features but you will not be able to change anyt...

Страница 12: ...ectronic systems occasionally have problems especially in portable systems that have a relatively hard life and where water and heat are involved Fortunately we have very few such problems but as an added benefit we have built into all iCool s a complete manual override system that allows your iCool to operate effectively even if parts of the electronics fail for whatever reason We do not publish ...

Страница 13: ...ic Ft per Minute 3 Speed 1100 Cubic Ft per Minute 3 Speed 1100 Cubic Ft per Minute Power Plug 3 Pin Heavy Duty 10 AMP Plug 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug 3 Pin Heavy Duty 10 AMP Plug Weight Kilos Pounds 40kg 85 Lbs 35kg 79Lbs 36kg 79 Lbs 39kg 85 Lbs Dimensions H W D Millimeters 610w x 630h x 325d 610 x 500 x 240 610 x 500 x 240 610 x 500 x 240 Dimensions H W D Inches 24 x 25 x 12 5 24 x ...

Страница 14: ...All iCool Machines are Designed Manufactured in Australia Published 2016 by iCool Australia Pty Ltd iCool is a Registered Trade Mark worldwide Contact info icoolsport com www icoolsport com ...

Отзывы: