iConyx IC8A Скачать руководство пользователя страница 4

INTRODUCTION

Congratulations on your purchase of a Renkus-Heinz Iconyx Steerable Column Loudspeaker. We hope you enjoy it.

Your Iconyx Steerable Column Loudspeaker was carefully tested and inspected before leaving our factory and should have arrived in

perfect condition. Please carefully inspect the shipping carton(s) and loudspeaker(s) for any noticeable damage, and if any damage

is found, immediately notify the shipping company.

Only you, the consignee, may institute a claim with the carrier for any damage incurred during shipping. Be sure to save the car-

ton(s) and all packing material for the carrier’s inspection.

It is also a good idea to save the carton and packing material even though the loudspeaker arrived in good condition. If you should

ever need to ship the loudspeaker, it should be shipped in its original factory packaging.

GENERAL INFORMATION

To simplify shipping and handling, ICONYX arrays are constructed from 8-channel or 16-channel modules and need to be assembled

in the field. The assembly hardware is packed with the modules in cardboard box(es) that double as carton “fillers”. The ones con-

taining the hardware are marked “Hardware” to prevent their being accidently discarded.

If you purchased an

IC8A

or

IC16/8A

, all you need to do is remove the column loudspeaker and its hardware box from the carton

and install it. Skip to page 9 for Address Number Verification instructions.

If you purchased an

IC16A

or an

IC32/16A

, you should have received two cartons (two 8-channel or 2-16 channel modules) and will

need to assemble them into a 16- or 32-channel unit. Each carton will include a hardware box, but if you purchased an IC16A only

the box in carton 1 will include hardware; the box in carton 2 will be empty. If you purchased an IC32/16A, both boxes will include

hardware.

If you purchased an

IC24A

, you should have received 3 cartons (three 8-channel modules). The hardware boxes in cartons 1 and 2

will include hardware, while the box in carton 3 will be empty.

If you purchased an

IC32A

, you should have received 4 cartons (four 8-channel modules) and will need to assemble them. The

hardware boxes in cartons 1, 2 and 3 will include hardware; the box in carton 4 will be empty.

A detailed listing of the hardware supplied with each model follows on the next page. The cartons will be marked to show the mod-

ules’ position in the finished column array; for example, top, bottom, center, etc.

In all cases, if you ordered a mounting hinge kit with the loudspeaker the female portions of the hinge assemblies will have been

installed on the modules for you. The male portions of the wall mounting hinge assemblies will be packed in the hardware box(es). A

dimensional drawing of the column array and paper mounting templates were included in the plastic bag that contained this manual.

Note that the male sections have been set up to allow the column to swing to the right away from the wall. If you want the column to

swing to the left, you will need to change the location of the hinges from the right side of the wall mounting plate to the left side.

Refer to the Installation section of this manual for more information.

4

Owners Manual

Содержание IC8A

Страница 1: ...Owners Manual Owners Manual OWNERS MANUAL IC8A IC16A IC16 8A IC24A IC32A IC32 16A Assembly Installation Instructions...

Страница 2: ...near water The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on it 6 Clean only with dry cloth 7 Do not block any ventilatio...

Страница 3: ...nstallation Cabling Required 42 Power 42 Audio Digital Contol 42 Installation 42 Wall Mounting 42 Suspended Flying 45 Servicing 46 Trouble Shooting Hints 46 TECHNICAL SUPPORT Owners Manual If you have...

Страница 4: ...cartons two 8 channel or 2 16 channel modules and will need to assemble them into a 16 or 32 channel unit Each carton will include a hardware box but if you purchased an IC16A only the box in carton...

Страница 5: ...M4 Philips flat head machine screws M5 Philips pan head machine screws Wall Mtg hinge plates If hinge kit was purchased Model IC8A IC16 8A Model IC16A IC32 16A Model IC24A Model IC32A Box 1 1 4 2 1 1...

Страница 6: ...a Hint The lower end of each module is the end of the module with the access plate for the power cord input connections and programming cable In the graphic shown below the access plates were removed...

Страница 7: ...sary use a flashlight to check because if the connectors are not seated properly you may have to disassemble the column again in order to seat them correctly 10 Align the two modules and slide them to...

Страница 8: ...hat hold the heavy joining plate in place Turn the assembly on its side and tighten the screws 14 If you are assembling an IC24A IC32A or IC32 16A repeat the assembly procedure until all the modules a...

Страница 9: ...ches are set at the factory based on the size and quantity of steerable column loudspeakers ordered You may want to check and record these settings before installing the loudspeakers It is a lot easie...

Страница 10: ...etup Once the setup is completed the PC is no longer needed unless the system parameters need to be adjusted or changed The Iconyx software requires a PC meeting at least the following basic requireme...

Страница 11: ...pter it must have a communications speed of at least 9600 baud The Iconyx Software CD you received with your Steerable Column Loudspeaker includes the driver needed by the USB to RS422 adapter plus 2...

Страница 12: ...stallation make sure the USB to RS422 converter and serial extension cable is not connected to any of the Iconyx column arrays FOR WINDOWS VISTA USERS Use Windows Update to find the correct driver FOR...

Страница 13: ...river you will be notified that the driver has not passed Windows Logo testing with the following message Click on Continue Anyway Windows will finish the driver installation Click on Finish when prom...

Страница 14: ...o RS422 adapter driver installation FOR WINDOWS 2000 USERS 1 With the PC on and Windows running insert the Iconyx Software CD into your CD drive Connect the USB to RS422 adapter to an available USB1 1...

Страница 15: ...ted to install it click on Next After Windows finishes installing the driver click Finish when prompted 4 Windows will now find another hardware device which is the Serial Port device of the adapter c...

Страница 16: ...following screen Click Search for a suitable driver for my device Recommended and then click Next 6 You will be prompted for a location to search for the drivers Click CD ROM Drives then click on Next...

Страница 17: ...indows did not prompt you as in step 1 you will need to manually initate the driver installation Open Device Manager by Right Clicking on MyComputer and selecting Manage Click on the Device Manager ic...

Страница 18: ...you must uninstall it using Add Remove Program Beamware 2 requires that Microsoft s NETFramework 2 0 or higher be installed on your computer and if you do not have it installed on your computer will g...

Страница 19: ...Make your choice and then approve the suggested file location by clicking on Next A Confirm Installation window will open Approve the installation by clicking on Next When the Installation Complete w...

Страница 20: ...suggested file location by clicking on Next C Select the Icon Option you wish to use and then click on Next to continue D Click on Install to begin the installation E Click on Done to complete the ins...

Страница 21: ...pull down menu and select Layout Presets Then choose one of the example floor plans You can also create your own floor plan and import it into the Project All that is required is an outline drawing sa...

Страница 22: ...then select the desired array You can also right click on the floor plan graphic and then select Add Array from the pop up menu Notice that when you use this method the coverage graphic is automatical...

Страница 23: ...one of them see below Note that the program will not allow you to enter the Array Properties section until you have added an array to the project Select the array you want to work with and press OK t...

Страница 24: ...suggest you accept the default setting There are times however when you will want to change the height of the measuring plane It is set to 1 2 meters 3 94 feet which is fine for a seated audience but...

Страница 25: ...udience Area size s and location s to match your project s dimensions Notice that you can also add or delete up to a maximum of 3 Audience Areas by using the Number field and associated drop down arro...

Страница 26: ...above the Floor level the 0 level The default position is 6 56 feet 2 meters The Mechanical Angle field tilts the column forward or backward minus numbers tip it back and plus numbers tilt it forward...

Страница 27: ...e change You will also need to do a new Calculate Mapping to view the change The old map will have been wiped out by the program as you made the change Note that you can also check Focal Point ft and...

Страница 28: ...ovide the desired coverage Rooms with a balcony are a good example in most cases a single beam can t cover both the main floor and the balcony One solution is two line arrays one for the floor and the...

Страница 29: ...ther words either beam can be above or below the other one In fact both beams could have their acoustical center at the same location The only difference is that the level of Beam 2 can be reduced by...

Страница 30: ...cannot get good coverage on the front of the audience area You will either need to add front fill loudspeakers or lower the column The following screen shows what can be accomplished with the column...

Страница 31: ...ore beams You ll find it in the IC Configuration sectionnext to Beams Clicking on Auto Focus will open the setup window shown below Notice that it gives you the option of dictating the location of the...

Страница 32: ...may how ever want to try moving the array up or down to see if you can find a better location for the Iconyx array or use more or fewer beams to see it you can eliminate this warning prompt At this po...

Страница 33: ...EASE JR It s a simple thing to do just open the EASE Iconyx DLL file into your EASE project in the normal fashion and then click on Load Setup to import all the Beamware settings into EASE If you have...

Страница 34: ...A module Arrays are made from these Columns modules In Beamware 2 these relationships are stored in the following manner every Column has a unique ID ICID number and every Array has a unique ID Array...

Страница 35: ...Network to deter mine what Columns are available Note that you may have to adjust the Columns in Network section of the window to see the entire listing The next step is to scan the network for Colum...

Страница 36: ...Beamware 2 are linked together The easiest way to assign one of the Columns to an Array is to grab it using the cursor and left mouse button and drag it to one of the Column icons Notice that the col...

Страница 37: ...window and explore the two setup options we ignored earlier see page 35 The Scan for new Arrays on network option is similiar to the Scan for Columns on network option except that it also identifies...

Страница 38: ...down arrow You also have a choice of initializing the column array to the default setting or of retrieving the column array s previ ous settings We recommend that you use Retrieve current settings fro...

Страница 39: ...response The High Pass Filter button inserts a high pass filter into the signal chain and allow you to dial in any low frequency roll off you desire It was preset to 100 Hz with a 24 dB per octave sl...

Страница 40: ...des access to an 8 band parametric EQ allowing you to adjust the response to compensate for any room acoustic pecularities The Master Level button allows you to control the output level of the column...

Страница 41: ...s you to choose the signal s frequency and distribute the signal to the column array Please note that any changes are not saved in the column array s memory until you have activated the Save set tings...

Страница 42: ...rd with IEC connectors Note that the column s do not include a power on off switch and you will have to make sure an external power on off switch is provided Each module however does include a self re...

Страница 43: ...hs a terminating resistor may be necessary The data connectors for the digital control line are a standard 9 pin DB 9 connector and a 7 pin Phoenix connector These are also in parallel and either can...

Страница 44: ...power is turned on the contact changes to closed The contact then goes open if that column faults out or the power shuts off Combination AC Mode 3 is the most popular one and the one used on all order...

Страница 45: ...it is to hold the actual mounting plates in place while marking Hint To simplify the mounting many installers will first cut a backing plate the size of the column out of heavy plywood and mount the...

Страница 46: ...improper or poor ground on the audio signal line Check the program souce to make sure the hum isn t originating there Carefully check all the audio connections to make sure they are properly made Noi...

Страница 47: ...array is no longer receiving power Reset the circuit breaker to see if this cures the problem If it doesn t or if the power comes on for only a brief period of time and then goes out again either the...

Страница 48: ...3 Disconnect unplug the module from the signal buss line See below 4 Disconnect unplug the module from the output buss line 5 Disconnect unplug the module from the AC power buss line Owners Manual 48...

Страница 49: ...ed to rotate it 90 degrees to gain access to the screws 7 Move the assembly slightly toward the top of the module and then carefully lift the assembly out through the side of the cabinet Note that whe...

Страница 50: ...RH 636 August 08 19201 Cook Street Foothill Ranch CA USA Phone 1 949 588 9997 Fax 1 949 588 9514 sales renkus heinz com www renkus heinz com...