iControl Remote Installation Manual
ICRIM-EN-
April 20
20
7
Section Title
77
77
Installation, connections and commissioning
• For pivots with BASIC A/R panel: The PINK wire should be connected to Terminal T7 instead of
Terminal T3. From this moment, iControl Remote will have a supply voltage of 110 VAC.
• For pivots with STANDARD A/R panel:
a) The YELLOW/RED wire must be connected to Terminal T23. From this moment, iControl Remote
will have a supply voltage of 110 VAC.
b) The PINK wire must be connected to Terminal T24 to enable the iControl Remote to control a pump/
valve, as indicated in step 2.
8. Connect the pivot energy supply.
9. Access the web address https://icontrolremote.com . You will be asked to enter a user name and
password: use the last six digits of the iControl Remote serial number. For example, for the serial
number 357042061393945, the default user name is: 393945 and the password is: 393945.
Note: This login is provisional for the installer, and it will be canceled once the controller is assigned
to its owner in the administration platform (iCAP). It is very important that once the installation is com
plete, the equipment should be assigned to its owner in iCAP.
10. An interface similar to that shown on previous pages will appear, which includes a widget for the iCon
trol Remote device that has just been installed.
11 . Congratulations! You can now configure this pivot from its control panel and access the iControl
Remote Cloud service remotely https://icontrolremote.com.
12. In the first place, the correct coordinates of the pivot point must be established. This can be done in
the Setup tab by entering the coordinates directly, or else you can obtain them if using a mobile device
by clicking the Use the GPS location button in your telephone.
13. For further information read the iControl Remote manual or contact the local assistance service. For
security reasons, assigning an owner in iCAP is required as soon as possible to disable the 6-digit
installer username.