18
Inspect and tighten all parts of the exercise bike regu-
larly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap. IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
Most console problems are the result of low batteries.
See assembly step 7 on page 8 for battery replace-
ment instructions.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 15.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed
switch, you must first
remove the Shield
Cover (12). Using
a flat screwdriver,
release the tabs on
the Shield Cover, and
then lift the Shield
Cover away from the
frame.
Next, locate the Reed Switch (46). Loosen, but do not
remove, the M4 x 16mm Screw (61).
Next, rotate the Pulley (43) until a Magnet (44) is
aligned with the Reed Switch (46). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 16mm Screw (61).
Rotate the Pulley (43) for a moment. Repeat these
actions until the console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the shield cover.
MAINTENANCE AND TROUBLESHOOTING
12
61
46
43
44