16. Trouble Shooting Guide

 

 

 

Causes unrelated to the 

controller 

Unit related causes 

The pump 

will not start 

1.  Voltage Failure 
      Is the 

GREEN LED 

      'POWER'

 illuminated? 

2.  Pump no longer  
     operational. 
3.  Wiring inverted  
     (line/motor) 

1.  Ensure the controller ON/OFF button is ON. 
2.  Check the controller isn't in error mode with  
     the 

RED LED 

'LACK OF WATER' illuminated or  

     the display showing -P-, -A-, OL, UL, PF or Pr  

3.  Controller Only option

:  

         

check the controller to pump wiring.

 

4.  Ensure the water column above the controller  
     isn't greater than the cut in pressure.  
5.  Internal electronics may have failed due to a 
     lightning strike or power surge 

The pump 

doesn’t stop  

1.  There may be leaks 
greater than the minimum 
flow requirement. 
(nominal 0.9 l/min) 
  

Note: Check discharge 

   and intake for losses

 

1.  PF (low flow protection) setting may be 

disabled   

2.  Inspect the internal check valve 
3.  Excessive iron oxide disrupting operation 
4.  Internal electronics may be damaged 

Pump Failure 

1.  Water failure 
2.  Suction problems 

Pump failure is not necessarily the fault of the 

controller 

RED LED

 

'LACK OF 

WATER' 
Flashing  

1.  Pump not primed or  
     has lost prime 
2.  Water shortage. Valve 
     on suction closed? 
3.  Air pockets or leaks in 
     the suction line 
4.  Pump thermal 
     protection activated 
5.  Pump head less than 
     cut in pressure. 

  

Display -P- 

    The actual pressure in 
    the pipeline has been 
    more than 9.9 Bar for 
    longer than 5 seconds 

1.  The controller may be damaged 
2.  The pressure sensor may be damaged 

Display -A- 

   Check for leaking taps, 
   float valves, or non-  
   return valves/foot valves 

For the last 15 times the pump has run for less 

than 30 sec 

Display OL 

   Possible pump fault 

 Indicates Power Overload 
 Check the OL set value is correct 

Display UL 

   Lack of water (dry run) 

 Indicates Power Underload 
 Check the UL set value is correct 

Display Pr 

Tap left open 
or  
broken pipe 

Pump has been running continuously, exceeding 
time value of Pr setting. 
Cut-out pressure (Mode 2) is greater than the pump 
can deliver. 
Reset by cycling power to controller. 

 

Содержание NXT Pro

Страница 1: ...1 Auto Restart Pump Controller iCON NXT Pro User Manual 808035 BIA NXTPRO...

Страница 2: ...when the upper setting is achieved Both the start and stop pressure can be selected by the user A Pressure Tank is required if operating in Mode 2 The iCON NXT Pro offers a number of other protection...

Страница 3: ...l specifications 5 6 Warnings 6 6 1 Cautions 7 7 Electrical Connections 8 8 Display 9 9 Programming 10 10 Installation 11 11 Priming the system 12 12 Standards and Approvals 12 13 Operation 13 14 nXt...

Страница 4: ...s manual Warning Electrical safety Warning Potential consequences of use outside of intended application s Includes environmental condition warnings Mandatory warning Warning to disconnect power Read...

Страница 5: ...ccumulator removed Pump Start pressure Default 2 2 bar User adjustable 0 5 6 0 bar Pump stop Flow less than 0 9 lpm in Mode 1 User adjustable 1 8 9 0 bar in Mode 2 Maximum pressure 10 bar Pressure dif...

Страница 6: ...ers to protect the power supply The fitment of additional surge protection is recommended Never open the cover while controller is connected to electrical supply This appliance is not intended for use...

Страница 7: ...NXT Pro controller It should not be dismantled 6 1 5 No regular maintenance of the NXT Pro controller is required 6 1 6 Fitment and replacement must be carried out by competent skilled and qualified...

Страница 8: ...lead and AS NZ 3112 Type 1 3 pin male power plug for connecting to mains power The Plug and Play version of the iCON NXT Pro is fitted with a 10 amp rated IEC C13 appliance connector When the iCON NXT...

Страница 9: ...PROGRAMMING PX X Start and Stop Pressure CX X Current F1 Mode 1 pressure controller Default cut in 2 2 bar F2 Mode 2 pressure switch Default cut in 2 2 bar Default cut out 9 bar OL Overload protection...

Страница 10: ...gramming Important Note The controller allows for a maximum of 10 seconds between button presses when programming If no button press is detected after 10 seconds the controller will exit the adjustmen...

Страница 11: ...head pressure of water above the controller is less that the starting cut in pressure otherwise the pump will not start See table below The controller is to be installed on the discharge of the pump p...

Страница 12: ...en to comply with the safety requirements of the applicable Australian Standard Pumps that carry the AS NZ4020 Drinking Water Approval demonstrate compliance with requirements of Australia New Zealand...

Страница 13: ...ar Set to Mode 1 the iCon NXT Pro controller will stop the pump for 4 reasons Once flow has stopped due to a tap being closed In the event that the pump has run out of water If the control is subject...

Страница 14: ...xceeded Pushing the RESET button rotates the display indication System Pressure Current Draw Operational Status Underload Dry Run condition assumes the Pipe Flow parameter PF is enabled The following...

Страница 15: ...id that a pressure vessel is essential Most systems suffer from small water losses dripping taps leaking cisterns feeding low demand items such as ice makers or Reverse Osmosis filtration units the ad...

Страница 16: ...0 Cth for goods purchased in Australia and the Consumer Guarantees Act 1993 NZ for goods purchased in New Zealand 4 Our goods come with guarantees that cannot be excluded under the Australian Consumer...

Страница 17: ...g operation 4 Internal electronics may be damaged Pump Failure 1 Water failure 2 Suction problems Pump failure is not necessarily the fault of the controller RED LED LACK OF WATER Flashing 1 Pump not...

Страница 18: ...18 17 Notes...

Страница 19: ...19 18 Notes...

Страница 20: ...changes in product specifications 2020 Copyright White International Pty Ltd TM WARNING Please be aware that various brands products depicted within this document are subject to trademark patent or de...

Отзывы: