R
Submersible Sensors
All Submersible Sensors have a Calibrated Range that is Based
on H
2
O that has a Specific Gravity or Density = 1
Range Value :
The Overall Measuring Distance
that the Sensor has been calibrated to by
the Factory - The Range will be Located on the Sensor Body
1.
Empty
: The Pressure being exerted on
from the sensor diaphragm at Lowest Point
Normally this is when the Tank is Empty within the Tank
Empty = 4mA setting.
2.
Full :
The Pressure being exerted on the sensor’s
diaphragm at the highest point Liquid Level within
the Tank
Full = 20mA setting.
3.
Chemical
Concentration
Specific Gravity
Temperature
Solids :
Out-gassing or Vapors :
Tank Dimensions W x H inches :
W = H =
Vertical : Horizontal :
Flat Bottom : Conical Bottom :
Yes
No
Yes
No
Liquid
Exerts
Pressure on
Diaphragm
100%
20mA = Full
4mA = Empty
0%
Range
Understanding Level Measurement
Application Details
Diesel
DEF
Chemicals
R
Sensor Diaphragm
www.iconprocon.com | [email protected] | 905.469.9283