ICON Levelpro 300S Series Скачать руководство пользователя страница 1

Submersible Level Sensors

300S Series

Operating Manual

Continuous Submersible Level Sensor

300S Series

R

www.iconprocon.com | [email protected] | 905.469.9283

Diesel

DEF

Chemicals

R

Содержание Levelpro 300S Series

Страница 1: ...Submersible Level Sensors 300S Series Operating Manual Continuous Submersible Level Sensor 300S Series R www iconprocon com sales iconprocon com 905 469 9283 Diesel DEF Chemicals R...

Страница 2: ...250B Display Connection Diagram Sensor TVL Display Connection Diagram Sensor Sentinel LTE TVL Display Understanding Level Measurement Application Details Getting Started Calculating Max Range of Sens...

Страница 3: ...evice and should be kept nearest its location always accessible to all employees This operating manual is copyrighted The contents of this operating manual reflect the version available at the time of...

Страница 4: ...after mainte nance work the probe has to be submerged slowly into the medium A rough immersion into the medium can damage or destroy the diaphragm If there is any danger of damage by lightning or ove...

Страница 5: ...K 0 1 Full Scale Over One Year Response Time 10 msec Thermal Effects Offset and Span Permissible Temperatures Electrical Protection Thermal Drift 0 02 FSO K in Compensated Range 13 F 178 F 25 C 85 C S...

Страница 6: ...re After Features New Vaporbloc Technology NEMA 4X Enclosure Tool Free Wiring Terminals All Plastic NEMA 4X Enclosure 2 Threaded Connection Excellent Chemical Resistance Weather Resistant Gortex Air B...

Страница 7: ...Technology for Outdoor Applications No Assembly Required 8 Levels of Brightness Signal Peak Value Detection Dampens Noise 3 Wire Cord Grips Included No Add Ons Relay Lights Audible Alarm Function Comp...

Страница 8: ...hrough Cable Gland Remove Heat Shrink Discard Heat Shrink Remove Filter from Vent Tube Feed Wires through VaporBloc Ensure VaporBloc is Oriented Correctly Sensor Junction Box Installation www iconproc...

Страница 9: ...rBloc Installed Take Junction Box Open Lid Open Lid Fuming Liquids Please Install VaporBloc 1 Feed Sensor Red and Black Wire Breather into Junction Box 2 Tighten Cord Grip 1 4 Turn Lid is Tethered Do...

Страница 10: ...Tighten Only Connection Diagram Sensor 250B Display 300S Series Level Sensor Supply Supply Vs Red Black Sensor Wire Red Terminal 1 Black Terminal 3 Red Terminal 2 Black Terminal 4 300S Series Sensor 1...

Страница 11: ...ay 4 20 Output Examples Pump Shut Off Valve Shut Off Wiring to a Loop Powered Display 300S Series Level Sensors 1 2 3 4 5 6 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Power Supply 120VAC Terminal 1 2 TVL...

Страница 12: ...2 3 4 5 6 Junction Box Terminals Green wire Terminal 5 Black wire Terminal 4 Junction Box Terminals Red wire Terminal 3 Black wire Terminal 2 13 12 11 10 09 08 07 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6...

Страница 13: ...he Tank Empty 4mA setting 2 Full The Pressure being exerted on the sensor s diaphragm at the highest point Liquid Level within the Tank Full 20mA setting 3 Chemical Concentration Specific Gravity Temp...

Страница 14: ...e sensor range changes when submersed into liquids with different Specific Gravities Please note that the physical location of the level transmitter will indicate the lowest level of measurement withi...

Страница 15: ...he sensor has increased and is now 64 or 816 The liquid in Tank 2 has a S G 2 which is 2X Heavier than H20 The 34 sensor is now going to be installed into a tank to measure a liquid with a S G 2 Range...

Страница 16: ...inated at a LP100 junction box located on top of the tank Since the vent tube is contained within the cable the pressure within the junction box A Gortex Breather to ensure accurate atmospheric pressu...

Страница 17: ...be is fitted with a Gortex Filter this must remain attached in order to prevent moisture particulate or insects from entering Do Not Remove Avoid blocking or bending the ventilation tube The LP100 Ins...

Страница 18: ...cal mechanical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to repair 5 have b...

Страница 19: ......

Отзывы: