background image

Technical Specifications

Input Pressure Range

Performance

Level ft/H

2

O

Overpressure 

psi

14 

20 

34 

54

14X 

14X 

10X 

10X

Output Signal | Supply

Standard

Power Supply

4-20mA | 4-20mA + Hart 2 Wire | 0.5-4.5 VDC Ratiometric | 0-5 VDC | RS-485 3 Wire

4-20mA | 24 VDC  ||  0.5-4.5VDC Ratiometric  ||  0.5-4.5VDC } 5VDC  ||  RS-485 HART } 24VDC

Accuracy

Permissible Load

Influence Effects

Long Term Stability

Response Time

<±.25% Std | .125% Opt

R

max

 = [(Vs-Vs

min

)/0.02 A] 

<± 0.1% Full Scale Over One Year

<150 msec or better

Supply :

 0.05% Full Scale / 10V

Load :

 0.05% Full Scale / K

Thermal Effects | Offset and Span

Thermal Error

<± 0.2% FSO/K in Compensated Range -20°F - 178°F

Temperatures

Operating Temperatures

PVC

 -32°F - 140°F    |    

PP

 -20°F - 178°F    |    

PVDF

 -40°F - 212°F    |    

PTFE

 -40°F - 212°F

Electrical Protection

Short-Circuit Protection

Reverse Polarity Protection

Permanent

No Damage to Sensor

Electromagnetic Compatibility

Short-Circuit Protection

Emission Immunity According to EN 61326

Permanent

Electrical Connection

Jacketed Cable

3-Wire Cable with Integrated Air Tube for Reference to Atmospheric Pressure

PTFE | Teflon

®

 -40 - 200°F

Materials | Wetted

Housing

Seal

PVC | PP | PVDF | PTFE Teflon

®

FFKM - Kalrez

®

Diaphragm

Pure Ceramic 99.9% AI203

Electrical Protection

Current Consumption

Weight Grams

Max. 25mA

PVC 575g | PP 475g | PVDF 825g | PTFE Teflon

®

 875g

Ingress Protection

CE-Conformity

IP 68

EMC Directive: 2004 | 108 | EC

www.iconprocon.com | [email protected] | 905.469.9283

05

Continuous Submersible Level Transmitter

200C Series 

(Capacitive Ceramic)

R

Содержание Level pro 200C Series

Страница 1: ...esel DEF Chemicals Submersible Level Sensors 200C Series Operating Manual Continuous Submersible Level Transmitter 200C Series Capacitive Ceramic R www iconprocon com sales iconprocon com 905 469 9283...

Страница 2: ...y Connection Diagram Sensor TVL Display Connection Diagram Sensor Sentinel LTE TVL Display Understanding Level Measurement Application Details Getting Started Calculating Max Range of Sensor Correctio...

Страница 3: ...issued to our best knowledge Levelpro is not liable for any incorrect statements and their effects www iconprocon com sales iconprocon com 905 469 9283 03 Continuous Submersible Level Transmitter 200C...

Страница 4: ...the probe has to be submerged slowly into the medium A rough immersion into the medium can damage or destroy the diaphragm If there is any danger of damage by lightning or overpressure when the device...

Страница 5: ...g Temperatures PVC 32 F 140 F PP 20 F 178 F PVDF 40 F 212 F PTFE 40 F 212 F Electrical Protection Short Circuit Protection Reverse Polarity Protection Permanent No Damage to Sensor Electromagnetic Com...

Страница 6: ...inuous Submersible Level Transmitter 200C Series Capacitive Ceramic R Before After Features New Vaporbloc Technology NEMA 4X Enclosure Tool Free Wiring Terminals All Plastic NEMA 4X Enclosure 2 Thread...

Страница 7: ...or Adjustable Relay Timer NEMA 4X Enclosure LED Display All Plastic Corrosion Resistant All Cord Grips Included Simple Programming Features SunBright Technology for Outdoor Applications No Assembly Re...

Страница 8: ...ble Gland Remove Heat Shrink Discard Heat Shrink Remove Filter from Vent Tube Feed Wires through VaporBloc Ensure VaporBloc is Oriented Correctly Sensor Junction Box Installation www iconprocon com sa...

Страница 9: ...talled Take Junction Box Open Lid Open Lid Fuming Liquids Please Install VaporBloc 1 Feed Sensor Red and Black Wire Breather into Junction Box 2 Tighten Cord Grip 1 4 Turn Lid is Tethered Do Not Bend...

Страница 10: ...nd Tighten Only Connection Diagram Sensor 250B Display 200C Series Level Sensor Supply Supply Vs Red Black Sensor Wire Red Terminal 1 Black Terminal 3 Red Terminal 2 Black Terminal 4 200C Series Senso...

Страница 11: ...tput Examples Pump Shut Off Valve Shut Off Wiring to a Loop Powered Display 200C Series Level Sensors 1 2 3 4 5 6 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Power Supply 120VAC Terminal 1 2 TVL Channel Te...

Страница 12: ...6 Junction Box Terminals Green wire Terminal 5 Black wire Terminal 4 Junction Box Terminals Red wire Terminal 3 Black wire Terminal 2 13 12 11 10 09 08 07 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 2 wire sy...

Страница 13: ...mpty 4mA setting 2 Full The Pressure being exerted on the sensor s diaphragm at the highest point Liquid Level within the Tank Full 20mA setting 3 Chemical Concentration Specific Gravity Temperature S...

Страница 14: ...he submersible sensor range changes when submersed into liquids with different Specific Gravities Please note that the physical location of the level transmitter will indicate the lowest level of meas...

Страница 15: ...be in the tank S G 0 5 34 5 64 feet or 816 inches Since the oil is a lighter fluid than H20 the new measuring range of the sensor has increased and is now 64 or 816 The liquid in Tank 2 has a S G 2 wh...

Страница 16: ...a LP100 junction box located on top of the tank Since the vent tube is contained within the cable the pressure within the junction box A Gortex Breather to ensure accurate atmospheric pressure inside...

Страница 17: ...ted with a Gortex Filter this must remain attached in order to prevent moisture particulate or insects from entering Do Not Remove Avoid blocking or bending the ventilation tube The LP100 Installation...

Страница 18: ...ical or chemical damage due to improper accidental or negligent use 3 Have been modified or altered 4 Anyone other than service personnel authorized by Icon have attempted to repair 5 have been involv...

Страница 19: ......

Отзывы: