6.3 Mode of NPN Pulse Output TKP | TKM Models

ALt = 1

ALt = 0

ALt = 3

ALt = 2

Current Value = Flow Rate

Hys = Hysteresis ACTS Lika Buffer ± Around Pulse Output (Measured in GPM)

SV = Selected Value = Programmed Value (Customer)

CV < SV          ON: CV > SV + HyS          OFF

CV > SV          ON: CV < SV - HyS           OFF

SV + HyS > CV > SV - HyS         OFF: CV > SV + HyS or CV < SV - HyS         ON

SV + HyS > CV > SV - HyS         ON: CV > SV + HyS or CV < SV - HyS         OFF

DESCRIPTION

ALT NO.

6.4 K-Factors for TK

72

124

19

54

4.7

10.3

2.1

LPM

¾"

½"

1 ½"

1"

3"

2"

4"

Size

274

471

72

171

18

39

8

GPM

6.5 Programming TKS Model Only

F

SET

(Together)

OPERATION

DISPLAY

STEPS

Home Screen

Press        +

 

Step-1

TKS Series Only

Power Up Flow Meter with DC Power

000.0

(HOLD)

24V DC POWER ONLY

F

SET

Flow Meter

TKS

Alarm

GPM

Programming 

Lock

Output

Press         

Step-2

Programming Lock - Out Secure Feature

Lk = 10 (Unlocked Status) - 

(Default)

Changing Number will Lock Flow Meter

LK.10 (Default)

10 = Unlocked

If any other Number is entered the Programming will be restricted

F

SET

Flow Meter

TKS

Alarm

GPM

No Programming

Required K Value

Press         

Step-3

K-Factor Range : 0.1-999.9 (Depends on Meter Size - Factory Pre- Programmed)

K Value Preset (Do Not Change)

F

SET

Flow Meter

TKS

Alarm

GPM

Programming

Units 

of Flow

Press         

Step-4

Program Flow Units 0,1,2

Ut = 0 : (LPM)

Ut = 1 : (GPM) 

(Default)

Ut = 2 : {Kiloliter (KL)}

F

SET

Flow Meter

TKS

Alarm

GPM

Programming 

Communication

 

Output Type

Press         

Step-5

Programming NPN Pulse Output

con.E - Output = 1 Pulse / Gal

con.F - Paddle Pulse Output 5KHZ MAX-Remote Display

con.E (Default)

F

SET

Flow Meter

TKS

Alarm

GPM

Programming

of 

Relay

 Set Point

Press         

Step-6

Programming Relay Setpoint ON - OFF Options

Select - ALt.0,   ALt.1,   ALt.2,   ALt.3,

ALt.0 (Default)

See Next Page for Relay Alarm Options-

F

SET

Flow Meter

TKS

Alarm

GPM

Programming 

Relay

Time Delay

Press         

Step-7

Programming Initial Start-Up Relay Time Delay

Range : 0-99 sec Delay Time to Power on Alarm Output Relay

t.20 (Default)

 (20 Seconds)

Initial Start up of Flow Meter or Process (Allows for System

Steady State before Relay Switch becomes Active).

F

SET

Flow Meter

TKS

Alarm

GPM

         Required when Programming Remote

         Display or Controller

.

K-Factor Pre Programmed by Factory - No Flow Meter

Programming of a K-Factor is required.

© Icon Process Controls Ltd. All Rights Reserved

06

for more information visit www.iconprocon.com

Multi

-

Function Paddle Wheel Flow Meter

TKS

|

 TKP 

|

 TKM 

ROTATOR

 SERIES MANUAL

3

Содержание truflo TK Series

Страница 1: ...rves the right to implement changes without prior notice Programming Multi Function Paddle Wheel Flow Meter TKS TKP TKM ROTATOR SERIES MANUAL Icon Process Controls Ltd All Rights Reserved for more inf...

Страница 2: ...lay Chatter 6 7 Relay ON OFF Options For TKS Series Only 6 8 General Terms 7 Standard Pipe Size 8 Pressure vs Temperature psi water non shock 9 Wiring Diagram 9 1 TKP Flow Rate Flow Totalizer NPN Puls...

Страница 3: ...tistokes 2 Parts TK Series 3 Product Selection 1 2 3 4 5 6 7 EXAMPLE TKP 25 P E T RS M 1 SERIES e s l u P y a l e R h t i w r e t e M w o l F l e e h W e l d d a P S K T a b TKP Paddle Wheel Flow Mete...

Страница 4: ...amming Lock Out Feature TKP TKM Series Lck 10 Unlocked Factory Default IF Lck is Changed from the 10 the Flow Meter will be in Lockout Mode LCK 10 Default To Unlock ensure Lck is set to 10 Programming...

Страница 5: ...tep 5 TKP TKM Series Only CV Display Reads 0 SV Display Reads 0 0 Totalizer Default 0 0 Flow Rate Default CV Current Value SV Programmed Value 1000 Default One Pulse Per Gallon Default Flow Rate Pulse...

Страница 6: ...rogrammed K Value Preset Do Not Change F SET Flow Meter TKS Alarm GPM Programming Units of Flow Press Step 4 Program Flow Units 0 1 2 Ut 0 LPM Ut 1 GPM Default Ut 2 Kiloliter KL F SET Flow Meter TKS A...

Страница 7: ...6 7 Relay ON OFF Options For TKS Series Only ALt 1 ALt 0 ALt 3 ALt 2 CV Current Display Value Flow Rate d GPM Hysteresis Measured around Relay Set Point Measured in Gallons SV Selected Value Programm...

Страница 8: ...White 0V Totalizer Pulse Output NPN RS 485 1 OPT RS485 is a Special Order Item Flow Rate Pulse Output NPN Brown Yellow Grey Black 10 30 VDC 4 20mA or 0 5V Blue White 0V Totalizer Pulse Output NPN Tot...

Страница 9: ...NO COM Load 1 4 Grey 5 6 3 1 AMP TKP Yellow Grey wires with RS 485 Option Only Current output 4 20mA 120 max Voltage output 0 5V 10K min TKM Series 0 5VDC Optional 4 20mA is Standard Icon Process Cont...

Страница 10: ...er Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers max 10 Particle Size Not to Exceed 5mm Cross Section or Length Please do not...

Страница 11: ...cal or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repai...

Отзывы: