background image

TK SERIES

 MANUAL

Read carefully the instructions published in this manual before the first use of the sensor. Keep the manual

at a safe place. The manufacturer reserves the right to implement changes without prior notice

Programming

Multi

-

Function Paddle Wheel Flow Meter

TKS | TKP | TKM 

ROTATOR

 SERIES MANUAL

© Icon Process Controls Ltd. All Rights Reserved

for more information visit www.iconprocon.com

Flow Rate & Totalizer
Password Security Protected
Zirconium Ceramic | Rotor | Bearings

 

Display Rotates 360 Degrees
Bright LED Display

Содержание truflo TK Series

Страница 1: ...rves the right to implement changes without prior notice Programming Multi Function Paddle Wheel Flow Meter TKS TKP TKM ROTATOR SERIES MANUAL Icon Process Controls Ltd All Rights Reserved for more inf...

Страница 2: ...lay Chatter 6 7 Relay ON OFF Options For TKS Series Only 6 8 General Terms 7 Standard Pipe Size 8 Pressure vs Temperature psi water non shock 9 Wiring Diagram 9 1 TKP Flow Rate Flow Totalizer NPN Puls...

Страница 3: ...tistokes 2 Parts TK Series 3 Product Selection 1 2 3 4 5 6 7 EXAMPLE TKP 25 P E T RS M 1 SERIES e s l u P y a l e R h t i w r e t e M w o l F l e e h W e l d d a P S K T a b TKP Paddle Wheel Flow Mete...

Страница 4: ...amming Lock Out Feature TKP TKM Series Lck 10 Unlocked Factory Default IF Lck is Changed from the 10 the Flow Meter will be in Lockout Mode LCK 10 Default To Unlock ensure Lck is set to 10 Programming...

Страница 5: ...tep 5 TKP TKM Series Only CV Display Reads 0 SV Display Reads 0 0 Totalizer Default 0 0 Flow Rate Default CV Current Value SV Programmed Value 1000 Default One Pulse Per Gallon Default Flow Rate Pulse...

Страница 6: ...rogrammed K Value Preset Do Not Change F SET Flow Meter TKS Alarm GPM Programming Units of Flow Press Step 4 Program Flow Units 0 1 2 Ut 0 LPM Ut 1 GPM Default Ut 2 Kiloliter KL F SET Flow Meter TKS A...

Страница 7: ...6 7 Relay ON OFF Options For TKS Series Only ALt 1 ALt 0 ALt 3 ALt 2 CV Current Display Value Flow Rate d GPM Hysteresis Measured around Relay Set Point Measured in Gallons SV Selected Value Programm...

Страница 8: ...White 0V Totalizer Pulse Output NPN RS 485 1 OPT RS485 is a Special Order Item Flow Rate Pulse Output NPN Brown Yellow Grey Black 10 30 VDC 4 20mA or 0 5V Blue White 0V Totalizer Pulse Output NPN Tot...

Страница 9: ...NO COM Load 1 4 Grey 5 6 3 1 AMP TKP Yellow Grey wires with RS 485 Option Only Current output 4 20mA 120 max Voltage output 0 5V 10K min TKM Series 0 5VDC Optional 4 20mA is Standard Icon Process Cont...

Страница 10: ...er Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers max 10 Particle Size Not to Exceed 5mm Cross Section or Length Please do not...

Страница 11: ...cal or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repai...

Отзывы: