icon Audio Stereo 60 MK 3 Скачать руководство пользователя страница 6

Page 6 

source from the mains. One remedy for this is to 
use an interconnect which only has the screen 
connected at one end. Other causes of low-level 
hum can be from adjacent equipment, so 
experiment with moving equipment around to see 
if this makes the hum better or worse. 

 

One channel missing. 

Usually ‘bad’ connection on either the input or the 
speakers. Try swapping the connection over to 
establish if the cause is: 
(a) Input to the amp. 

Sound  will  move  to  the 

other channel. 
(b) Amplifier or speakers. 

Sound  will  not 

move. 

 

Strange noises coming from speakers 

Turn volume to minimum on unused input, if 
problem corrected either fault with source unit or 
with connection. If noise persists, problem with 
amplifier. 
If a whole output valve glows red (other than the 
heater), often accompanied by a hum through the 
speakers, switch off immediately, and refer to Icon 
Audio or a service engineer, as this could be valve 
failure. 
A valve that is lit up is not a guarantee that it is 
working properly; conversely a valve that is not lit 
up will not be working. 

 

Valve Replacement 

(see also section 7) 

Valve life will depend upon such things as hours 
of use and number of on/off cycles, the HT Delay 
Circuit if fitted will extend the life of valves by not 
stressing them when cold. It is not good practice 
to remove the valves unnecessarily as this can 
strain the pins and cause tiny air leaks.  

 

Service: 

Should you suspect a problem, you 

should return the unit to your agent/dealer or Icon 
Audio for a periodic service. In case of difficulty 
you could email or phone us. You could also 
return the valves to Icon UK for testing free of 
charge. Carefully remove the valves (the KT88s 
should be held by the base when removing, to 
prevent damage) numbering them with a marker 
or sticker from left to right from the front, in order 
that that may be replaced in the same position. 
They should be well packed in cardboard & foam 
or similar, (Valves are very rugged if packed 
properly). 

 

6 Specification & Features 

(Typical conditions @ 230v 50Hz) 

 

KT120/KT88 output valves or eqv (e.g. 6550) 

 

6SN7 phase splitter 

 

6SL7 first stage amplifier 

 0D3 

regulator 

 

Hand wired point to point components 

 

No printed circuit board 

 

Ceramic valve bases for low noise/leakage 

 

75w RMS* per ch Ultralinear 8

 KT120 

 

65w RMS* per ch Ultralinear 8

 KT88 

 

35w RMS* per channel Triode mode 8

 KT120 

 

30w RMS* per channel Triode mode 8

 KT88 

 

Typical gain 70 (integrated) 20 (power amp 

mode) 

 

Feedback: 4db High sens, 14db Low sensitivity 

 

Signal to noise level better than -97db 

 

Damping Factor= 13 @ 8

 triode & power amp mode 

 

Freq response 20Hz (-0.2db)-20khz - 0db any power 

 

Full power bandwidth 20Hz (-0.2db)-55khz - 3db

 

 

THD better than 0.25% at 40W 

 

4 and 8 ohms output taps 

 

Japanese EI transformer steel 

 

LDT Low Distortion Tertiary output transformers 

 

Choke regulated power supply 

 

0D3 voltage regulator 

 

Supplied with attractive valve cover 

 

3 potted transformers to reduce transformer noise 

 

High quality metal film & wire wound resistors 

 

High quality polypropylene audio caps 

 

Optional Jensen Copper, Silver or Alu foil caps 

 

Japanese ‘Blue’ ALPS volume pot. 

 Rubicon/Nichichron 

power 

capacitors. 

 

Audio wiring with silver Teflon cable 

 

Valves carefully matched for best performance 

 

Gold plated Input & speaker terminals  

 

Inputs for CD, Tape, Tuner, Aux 

 

Tape monitor output, buffered 

 

300mv sensitivity for full output (High sensitivity) 

 

950mv sensitivity for full output (Low sensitivity) 

 

230/240volts, 240watts (500 max) 

 

3.15 amp rear fuse (with spare) 

 

Internal HT fuses (spares inside) 

 

440W, 400D, 230H

, 35kg (Allow space for 

connections and ventilation) 

 

IEC mains lead, (plug 5amp fused) 

 

CE, ROHS, WEEE compliant 

* Refers to measured RMS voltage across 8 Ohms. 

(Specifications subject to change, errors & omissions excepted 20/12/11) 

 

Содержание Stereo 60 MK 3

Страница 1: ...riode The ST60 MKIII may also be used as a power amplifier The pre amp is a high quality Passive circuit using silver audio cable and an ALPS volume control It is sensitive enough to be used with all modern source equipment having an output of around 300mv or greater Its simplicity coupled with point to point hand wiring without the use of printed circuit board s results in an open euphoric sound ...

Страница 2: ...tor Output Valve Bias level Sound Quality Valve Microphony Valve Seating Hum level left right mv mv RF Test Power out 1 kHz 8ohms L R Channel Balance LED brightness Serial No sticker and recorded Mains voltage 110 230 240V IEC Mains Fuse 3 15 A HT int Spare 2x 1A F Fuses inc Soft Start Fitted Sales invoice Bottom label Credit card receipt Customer survey form Bias meter Remote send receive Remote ...

Страница 3: ...rmed by doing this We recommend you switch to standby when switching off to be ready for your next session 6a Integrated Power Amplifier Switch Located on the rear this switch is normally UP for integrated operation high sensitivity If use with a pre amplifier is required the switch should be DOWN in the low sensitivity position We would recommend use of the tape input with the volume on FULL or s...

Страница 4: ... It is important to use good quality loudspeaker cable This should be relatively thick and muti stranded i e QED Original or better Take care to connect the correct polarity The use of Banana plugs or spade connections will ensure a good connection whilst minimising the risk of shorts In our experience valve amplifiers are more tolerant of cables therefore some of the benefits of very exotic cable...

Страница 5: ...take several months of regular use before it is fully run in Upgrading Valves Good quality valves should sound better and have a good service life maintain their performance and be reliable the last three items will make a valve sound better longer The upgraded valves supplied with selected models are the result of careful comparison with other makes Cabinet Care To remove dust we suggest gentle b...

Страница 6: ...ticker from left to right from the front in order that that may be replaced in the same position They should be well packed in cardboard foam or similar Valves are very rugged if packed properly 6 Specification Features Typical conditions 230v 50Hz KT120 KT88 output valves or eqv e g 6550 6SN7 phase splitter 6SL7 first stage amplifier 0D3 regulator Hand wired point to point components No printed c...

Страница 7: ...to R 1 2 3 4 The bias adjustment pots from left to right are normally mirror image in rotation so some will be anti clockwise and some clockwise They are very sensitive so adjust very carefully use tiny turns of the screw If the reading appears a little unstable this is normally due to mains fluctuations 5 If one or more valves are showing very erratic readings or you cannot set the maximum to 330...

Страница 8: ... our website Exclusions Claims for any damage to either amplifiers or valves must be reported within three days of receipt Valves are classed as consumables on a 12 month reducing percentage of the cost of replacement This amplifier is designed for normal domestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has ...

Страница 9: ...cedure 1 With the top packing in place turn the box upside down with the flaps open 2 Lift the cardboard box off 3 Remove the bottom packing first 4 Turn the unit the right way up and remove the top packing Please be careful not to damage the small tape monitor and triode switches on the front panel When re packing ensure the two hand cut outs are towards the rear of the amplifier Please keep this...

Отзывы: