background image

Page 7 

use an interconnect which only has the screen 
connected at one end. Other causes of low-level 
hum can be from adjacent equipment, so 
experiment with moving equipment around to see 
if this makes the hum better or worse. 

 

One channel missing. 

Usually ‘bad’ connection on either the input or the 
speakers. Try swapping the connection over to 
establish if the cause is: 
(a) Input to the amp. 

Sound  will  move  to  the 

other channel. 
(b) Amplifier or speakers. 

Sound  will  not 

move. 

 

Strange noises coming from speakers 

Turn volume to minimum on unused input, if 
problem corrected either fault with source unit or 
with connection. If noise persists, problem with 
amplifier. 
If a whole output valve glows red (other than the 
heater), often accompanied by a hum through the 
speakers, switch off immediately, and refer to Icon 
Audio or a service engineer, as this could be valve 
failure. 
A valve that is lit up is not a guarantee that it is 
working properly; conversely a valve that is not lit 
up will not be working. 

 

Valve Replacement 

(see also section 7) 

Valve life will depend upon such things as hours 
of use and number of on/off cycles, the HT Delay 
Circuit if fitted will extend the life of valves by not 
stressing them when cold. It is not good practice 
to remove the valves unnecessarily as this can 
strain the pins and cause tiny air leaks.  

 

Service: 

Should you suspect a problem, you 

should return the unit to your agent/dealer or Icon 
Audio for a periodic service. In case of difficulty 
you could email or phone us. You could also 
return the valves to Icon UK for testing free of 
charge. Carefully remove the valves (the KT88s 
should be held by the base when removing, to 
prevent damage) numbering them with a marker 
or sticker from left to right from the front, in order 
that that may be replaced in the same position. 
They should be well packed in cardboard & foam 

or similar, (Valves are very rugged if packed 
properly). 

 

6 Specification & Features 

(Typical conditions @ 240v 50Hz) 

 

KT88 output valves or eqv (e.g. 6550) 

 

6SN7 phase splitter 

 

6SL7 first stage amplifier 

 

Hand wired point to point components 

 

No printed circuit board 

 

No tag board 

 

Ceramic valve bases for low noise/leakage 

 

65w RMS* per channel Ultralinear 

 

30w RMS* per channel Triode mode 

 

Signal to noise level better than -97db 

 

Freq response 20-20khz +or- 0.5db any power 

 

Power bandwidth 10hz-30khz 

 

THD better than 0.2% any power 

 

4 and 8 ohms output taps 

 

Japanese EI transformers 

 

Choke regulated power supply 

 

Supplied with attractive safety guard 

 

Minimal feedback used 

 

3 potted transformers to reduce noise 

 

High quality metal film & wire wound resistors 

 

High quality polypropylene audio caps 

 

Japanese ‘Blue’ ALPS volume pot. 

 

Rubicon/Philips power capacitors. 

 

Audio wiring with silver PTFE cable 

 

Valves carefully matched for best performance 

 

Gold plated Input & speaker terminals  

 

Inputs for CD, Tape, Tuner, Aux 

 

Tape monitor output, buffered 

 

300 mv sensitivity for full output 

 

230/240volts, 240watts (500 max) 

 

3 amp rear fuse (with spare) 

 

440W, 400D, 230H

, 30kg (remember to allow 

space for connections and ventilation) 

 

IEC mains lead, (5amp fused) 

 CE 

certified 

* Refers to measured RMS voltage across 8 Ohms. 

(Specifications subject to change, errors & omissions excepted 29/08/14) 

 

Содержание Stereo 60 MK 2

Страница 1: ...wiring hand wiring without the use of printed circuit board s results in an open euphoric sound that is wonderfully detailed and warm sounding In order to get the best out of your amplifier please rea...

Страница 2: ...Output Valve Bias level 500mv Sound Quality Valve Microphony Valve Seating Hum level left right mv mv RF Test Power out 1 kHz 8ohms L R Channel Balance LED brightness Serial No sticker and recorded M...

Страница 3: ...the switch should be DOWN in the low sensitivity position We would recommend use of the tape input with the volume on FULL or set as required and volume adjusted from your preamplifier although if yo...

Страница 4: ...00v DC which when switched off can take several minutes to discharge Do not remove bottom panel unless you are a competent engineer There are no user serviceable parts inside Like other household elec...

Страница 5: ...better and be cheaper to re arrange your room and use shorter cables than to spend a fortune on longer cables You can either hard wire your cable to the amplifier by baring enough cable to fit in the...

Страница 6: ...Valves Good quality valves should sound better and have a good service life maintain their performance and be reliable the last three items will make a valve sound better longer The upgrade valves su...

Страница 7: ...ne us You could also return the valves to Icon UK for testing free of charge Carefully remove the valves the KT88s should be held by the base when removing to prevent damage numbering them with a mark...

Страница 8: ...ockwise They are very sensitive so adjust very carefully use tiny turns of the screw If the reading appears a little unstable this is normally due to mains fluctuations 5 If one or more valves are sho...

Страница 9: ...es are classed as consumables on a 12 month reducing percentage of the cost of replacement LEDs used for aesthetic and d cor purposes are not covered These may be disconnected if not required This amp...

Страница 10: ...edure 1 With the top packing in place turn the box upside down with the flaps open 2 Lift the cardboard box off 3 Remove the bottom packing first 4 Turn the unit the right way up and remove the top pa...