IMPORTANT READ THESE NOTES THROUGH FIRST!
2 QUICK SET UP GUIDE
1 Unpack unit carefully
. Make sure that it is in good
condition. If not report to Icon Audio. It is important that
you keep the packaging for warranty/service return.
1
2 If Necessary fit the valves, or check that they are
firmly in place. Fit the valves according to the
numbers written on the base, normally L 1-5 and R
1-5 as printed on the copper plate.
The KT120s
should be fitted first to the two
REAR
sockets (the two
sockets nearest the transformers). To avoid damage to
the valves hold the valves as close to the base as
possible
NOTE THE “LEFT” and “RIGHT” KT120 orientation
on each amplifier. Also keep the left and right
amplifier valves separate. The right/left amplifiers
can be identified by the red or black ring on the
input sockets at the rear.
2
Be careful to note the correct orientation of the
central “spigot” between the pins otherwise damage
could occur.
3
The small valves should be gently & firmly pushed into
place. The 6SL7 (6188) is fitted to the right hand base
(the same side as the triode switch) and the 6SN7 to the
left hand base (the same side as the standby switch).
The 0D3 should be in the centre.
NOTE: The KT120s and 6SL7/6SN7 are NOT
interchangeable! This will result in damage and
could be dangerous.
4
3 Connect to source unit
, e.g. Phono pre amp,
Passive pre amp etc via appropriate phono sockets. Set
L & R SENSITIVITY switches on the rear to High (H) or
Low (L) as required, see 6a.
4 Connect speaker terminals
use “0” & “8 ohm”
terminals unless you have 4 ohm speakers (see P5)
Make sure that the polarity is correct. (See speaker
connections chapter 3). If ‘bi-wiring’ both ‘common’
should go to the black terminal and both ‘positive’ (or
red) should go to the red terminals.
5
5 Connect to mains
supply using supplied IEC mains
lead to 230v supply.
If for some reason the welded
plug must be removed, please remove plug fuse
and dispose of immediately.
(They can be a danger to
children if plugged in). The replacement plug should be
wired in the following way Brown to Live terminal, Blue
to Neutral terminal and Green/Yellow to Earth terminal.
6 Before switching on make sure that the “standby
switch” is in the “up” position.
6
SWITCH ON!
The blue LED mains indicator should light
up. Leave for at least 60 seconds for the valves to warm
up, and then push the “standby” switch into the “down”
position. The amplifier should now be working. Most
valves should have a visible orange glow from the
cathode heaters. With the pre amp volume control set to
minimum there should be no sound coming from the
speakers except a barely discernable hum. If there are
any unpleasant sounds coming from the speakers,
switch off and refer to the ‘Trouble Shooting’ section or
contact Icon Audio. We recommend you switch to
“standby” when switching off, (to be ready for your
next session).
6a High/Low Sensitivity Switch (on rear)
The LOW sensitivity position is designed to work with
normal valve and solid state pre amplifiers, giving the
best damping factor for “difficult load” speakers,
(normal feedback).
The HIGH sensitivity position is for “Passive” pre-amps
(without gain) or devices with a volume control (our
PS1/PS3 phono stage, MP3, “i Phone/Pod” etc).
Purists may prefer this low feedback sound. Feel free
to change and choose your preference.
7 Your unit should now be functioning
. If not check
wiring again. Do not operate at a high volume for the
first five minutes to allow the valves to warm up
properly.
All these things are normal for valve amplifiers:
A, Valves can get very hot, BEWARE!
B, The power transformer cover will get quite warm
C, The amplifier may smell a little for a few hours.
D, Mobile phone ‘breakthrough’ is normal.
E, Valves may make a ‘tinkling’ sound when warming
up and cooling down.
F, One channel may come on before the other at
switch on.
G, There may be a ‘click’ when switching off.
H, The occasional “click” or “pop” is normal.
8 Health and Safety
. The valves when operating have
high surface temperatures. Keep out of reach of
children and pets. The use of the supplied guard is
recommended in these circumstances. Always unplug
when making adjustments.
Like all amplifiers there
are potentially lethal high voltages inside (over
500v DC), which when switched off can take
twenty minutes to discharge!
Do not remove bottom
panel unless you are a competent engineer. There are
no user serviceable parts inside.
Like other
household electrical appliances do not leave
unattended whilst switched on.
Do not adjust the
KT120 bias pre sets without reference to the manual.
Incorrect adjustment could cause the valves to
overheat, with resulting
in damage to valves and
amplifier.
Bias Adjustment:
The bias adjustment is factory set. No initial
adjustment should be necessary. But it is
suggested that you test after shipping to ensure
the correct operation.
To maintain the best performance of the amplifier
you should check the bias of the output valves
from time to time (say twice a year). Full details
will be found in section 6.
For use of output valves other than KT120 see
section 6.