icon Audio MB 845 MK IIm Скачать руководство пользователя страница 9

*See engineers notes at rear

 

 

 

Page 9 

7 Valve Replacement

 

 

Important!

  Do  not  attempt  to  change  the  845 

output valves without reading these notes. Failure to 
do so could be both dangerous to you and damaging 
to the amplifier. Keep these notes handy. 

 

6SN7/6SL7  Take  care  that  you  orient  the  valve 
correctly  before  inserting.  Line  up  the  centre 
“Spigot”  first.  They  are  easy  to  break,  do  not  bend 
excessively to the side.

 

 

Health & safety; High voltages are present inside the 
amplifier and on exposed valve sockets when valves 
are  removed,  so  take  suitable  care.  It  is  not 
necessary  to  remove  the  bottom  cover.  Beware 
valves get hot in operation! 

 

How do I know when to replace valves? 

 

Valve life

 will depend upon such things as hours of use 

and  number  of  on/off  cycles.  It  is  not  good  practice  to 
remove  the  valves  unnecessarily  as  this  can  strain  the 
pins and cause tiny air leaks.  
In  our  experience  the  845  tube  is  very  reliable  and  can 
last  for  several  years  of  regular  use.  Similarly  with  the 
6SL7.  If  the  sound  deteriorates  after  approximately 
2000hrs  (2  years  @  3hr  per  day)  but  the  amplifier 
appears to be working OK suspect the 6SN7. 
Generally speaking valve failure may be one of these: 

1, The valve continues to work but the emission gets 
low.

  In  the  case  of  845  output  valves  this  will  result  in 

not being able to set the bias properly. 

2, The valve gets noisy/microphonic.

 Usually happens 

to  the  small  valves,  can  be  confirmed  by  tapping  gently 
with a plastic pen. 

3, Heater fails.

 No glow in centre of valve. Valve is cold. 

A valve that is lit up is not a guarantee that it is working 
properly;  conversely  a  valve  that  is  not  lit  up  will  not  be 
working at all. 

4,  Dramatic  Failure.

  Occasionally  the  demise  of  a 

power  valve  may  be  obvious  with  internal  sparks  and 
noise through the speakers. In that case, switch  off  and 
do  not  use  until  a  replacement  is  available.  Before  re-
commencing 

use  see  chapter  6  “Bias  Adjustment”.  If 

there  was  any  associated  burning  smell  etc,  we  would 
recommend  a  qualified  person  examines  the  inside  of 
the amplifier first. 

 

If the amplifier sounds OK the valves are probably fine. If 
the  emission  drops  you  will  have  difficulty  setting  the 
bias for the output valves.  

 
 

5, Changing valves:

  

Before changing the 845 valves ensure that it safe to do 
so by switching off and removing the mains plug at least 
20  minutes  before  hand.  This  will  enable  dangerous 
voltages to dissipate, and the valves to cool down. 

If  possible  check  the  bias  setting  before  you  attempt  to 
change  the  valve(s),  in  order  to  familiarise  yourself  with 
the procedure.  
If changing  both the 845s  be ready to adjust  the bias in 
order not to overload the power supply. 

Don’t worry how 

low the reading goes this will not cause damage. Do final 
adjustment when the amplifier is fully warmed up. 
If  all  is  well  there  should  be  no  more  than  a  barely 
detectable  hum  from  the  speakers,  and  the  amplifier 
should sound OK when tested. Note that only 845 valves 

are  compatible  with  the  amplifier,  805,  211  and 
similar  looking  tubes  cannot  be  biased  and  may 
damage the amplifier, and could be dangerous. 

 

6,

  If  you  cannot  set  the  pointer  in  the  black  section, 

then  the  valve  is  probably  faulty  or  is  unsuitable.  (If 
both valves read zero the HT fuse may have blown). 
If  the  valves  are  brand  new,  you  will  need  to  check 
again  after  approximately  10  &  100  hours,  after  that 
only occasionally or if you suspect a problem.  

 

7,  To  avoid  damage  to  the  amplifier  and  electric 
shock  hazard  you  must  use  only  valves  marked 
845,  6SL7,  6SN7  or  equivalent. 

Use  only  valves 

which you know to be new or good condition and test 
the amplifier thoroughly before resuming normal use.  

 

8, Replacing the small valves: 
6SL7 and 6SN7. 

Neither of these requires any set up 

procedure. 

It’s just ‘plug and play’. (These valves are 

similar  with  the  same  pin  connection;  accidentally 
interchanging  these  two  valves  would  not  cause 
damage, buy will reduce the amplifier performance). 
6SN7  should  only  be  replaced  with  modern  types. 
Vintage types and the Russian 6H30 type have lower 
ratings and are unlikely to work well. 

 

Icon  Audio  is  happy  to  check  the  valves/amp  or  re-
bias your amp free of charge. 
 

8 Specification & Features 

(Typical conditions @ 240v 50Hz) 

 

845 output valves 

 

6SL7 double triodes for first stage 

 

6SN7 double triodes for 2

nd

 stage 

 

Hand wired point to point components 

 

No printed circuit board or  

 

PTFE valve bases for low noise/leakage 

 

100w RMS at clipping (28.3v @8 Ohms) 

 

100w RMS at clipping (20v @4 Ohms) 

 

Signal to noise level -95db 

 

Freq response 20Hz-20kHz +or- 0.5db 

 

Power bandwidth -3db=20Hz-30kHz 90w 

 

0.01% THD typical 8w (0.015% 1w) 1khz 

 

Custom hand wound transformers using 
Japanese long grain steel 

 

Supplied with attractive safety guard 

 

Minimal feedback used 6db (high) 12db (low) 

 

High quality oversized metal film resistors 

 

Audiophile  High  quality  polypropylene  or  Jensen 
audio capacitors (optional upgrade) 

 

Internal wiring using silver audio cable 

 

Valves carefully matched for best performance 

 

Gold plated Input & speaker terminals  

 

400 mv sensitivity for full output (High) 

 

1v sensitivity for full output (Low)

 

 

 

230/240volts, 200watts (zero signal)

 

 

 

5  amp  (10  amp  115V)T  mains  rear  fuse  (with 

spare) 

 

250 ma T 845 anode fuses (with spares)

 

 

 

W: 20cm. D: 50cm. H: 22cm. Weight:35kg

 

 

 

IEC mains lead, (5amp fused UK only) 

 

CE certified. ROHS & WEEE compliant 

Specification subject to change without notice. 

 

Содержание MB 845 MK IIm

Страница 1: ...aler or one of our team Valve amplifiers do need a little more attention than their solid state counterparts but the sonic results are well worth it In this manual we have tried to include everything...

Страница 2: ...gs are less important This can be achieved by slowly rotating the V1 V2 screws on the top of the chassis make sure that you have the meter reading the correct valve e g adjust V1 whilst reading V1 If...

Страница 3: ...heck input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level L R mv RF Test LED brightness Serial No sticker and recorded Mains voltage 110 120 230 240V...

Страница 4: ...See engineers notes at rear Page 4 MB845 MK IIm Layout and Features...

Страница 5: ...in the following way Brown to Live terminal Blue to Neutral terminal and Green Yellow to Earth terminal 6 SWITCH ON The meter should light up and the 845s will glow bright yellow You will likely hear...

Страница 6: ...be out of phase with the sound stage inside out with reduced bass If you are unable to check this or confirm the polarity e g if you have built in wiring Another alternative is to use a test disc If y...

Страница 7: ...be as hot as the others Refer to an engineer or to Icon Audio Spare internal fuses are secured inside the chassis Replacements are available free of charge from Icon Audio 3 Hum Problems If you experi...

Страница 8: ...middle of the black section 3 How to adjust The adjustment is very sensitive so adjust very carefully If the reading appears a little unstable this is normally due to mains fluctuations Make sure you...

Страница 9: ...anging both the 845s be ready to adjust the bias in order not to overload the power supply Don t worry how low the reading goes this will not cause damage Do final adjustment when the amplifier is ful...

Страница 10: ...d for normal domestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has been modified in any way not approved by Ic...

Страница 11: ...he chassis with spares attached to the base If the fuse blows again a VARIAC or variable transformer will be useful to operate the amplifier on reduced power in order the trace the fault or overload M...

Отзывы: