![icon Audio BA2 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/icon-audio/ba2/ba2_instructions_3451330004.webp)
Page 4
Trouble Shooting
Amplifier Dead
Check the 1amp mains fuse which is in a “in line” fuse
holder adjacent to the front mains switch
Replacements should be 20mm 1Amp ‘anti-surge’ or
“T” type. These are available from Icon Audio should
you have any difficulty.
The fuse in the mains plug should be a 3 or 5 amp
fuse, although unlikely, this should be checked if the
amplifier fuse is OK.
No sound
Have you selected the right input? Are the
connections OK? Is everything switched on? Are the
speakers connected?
Distorted sound.
Try another source; if sound improves then it’s
probably something wrong with the first source. If no
improvement try different speakers, if no improvement
could be an amplifier problem.
Hum Problems
These are generally caused by “bad” earths or
A common cause is a ‘hum loop’ caused by having to
many earths, and may be identified by unplugging
each input source from the mains. One remedy for
this is to use an interconnect which only has the
screen connected at one end. Other causes of low-
level hum can be from adjacent equipment, so
experiment with moving equipment around to see if
this makes the hum better or worse.
One channel missing.
Usually ‘bad’ connection on either the input or the
speakers. Try swapping the connection over to
establish if the cause is:
(a) Input to the amp.
Sound will move to the other
channel.
(b) Amplifier or speakers.
Sound will not move.
Strange noises coming from speakers
Turn volume to minimum on unused input, if problem
corrected either fault with source unit or with
connection. If noise persists, problem with amplifier.
A valve that is lit up is not a guarantee that it is
working properly; conversely a valve that is not lit up
will not be working.
Valve Replacement
Valve life will depend upon such things as hours of
use and number of on/off cycles. As all the valves are
lightly loaded. As a rough guide we would estimate
life of approx 4 to 10 years. But this can vary.
What can happen?
A valves is at the end of it life if one of the following
happens:
•
6SN7s are twin triode valves. One of the two
heaters may fail.
•
A valve could get “noisy” or “microphonic”
•
The emission (and therefore output and
sound quality) may fall.
•
The valve works intremittantly.
•
An air leak causes the silver “getter” material
to turn white.
It is essential that only the correct valves are used
as some similar looking valves have a different
pin connection and insertion could result in
damage to the amplifier and risk of electric shock.
It is not good practice to remove the valves
unnecessarily as this can strain the pins and cause
tiny air leaks. Icon Audio are happy to replace valves
and check to performance of your amplifier, and
advise on the latest upgrades available.
Although the three original 6SN7 valves are normally
identical it is important that if they are removed, that
they are replaced in the same position. We suggest
you mark them, e.g. with a felt tipped pen.
Service:
Should you suspect a problem, you could
return the unit to your dealer or Icon Audio for a
periodic service or return the valves for testing free of
charge. You should carefully remove the valves they
should be well packed in cardboard & foam or similar,
and returned to Icon Audio for testing. (Valves are
very rugged if packed properly).
Specification & Features
•
No printed circuit board or tag board
•
All Triode design
•
2x 6SN7 Double triode
•
Signal to noise level -90db
•
Freq response 10hz-30khz +0 - 0.1db
•
THD 0.01%, @ 1khz, 2v rms
•
Hand wired point to point components
•
High quality 2w metal film resistors, for audio
•
Blue LED mains indicator
•
Audio grade Polypropylene audio capacitors
•
Wired with silver Teflon audiophile cable
•
Rubicon/Nichichron
power
capacitors
•
Ceramic valve holders for minimum leakage
•
DC heater power supply for minimum noise.
•
Gold plated Input & output terminals
•
Gain= 0.94 or -0.6db
•
Output impedance 38 ohms
•
Maximum output 30 volts
•
230/240volts, 15watts 1A anti-surge fuse
•
mains lead, (UK plug 5amp fused)
•
C E certified
•
SIZE and weight (figures in brackets allow for
rear
connections & ventilation)
(Specifications subject to change, errors & omissions excepted 21/03/08)
icon Audio
(UK) Ltd
351 Aylestone Road Leicester LE2 8TA
www.iconaudio.com
Ph +44 (0) 116 244 0593 +44 (0) 7787 158791