12
2.2
P
ARAMETER DESCRIPTIONS
Table 2: parameter description
S/N***:
Parameter
Range
Default
Unit
Parameter number
See §
Chosen value
Hardware
Configuration mode
[0, 1]
0
4
RF-channel
[0,3]
1
16
Detection
Speed unit
[0,1]
0
[km/h, mph]*
13
Communication
Baud rate
[0,4]
4
-
30
Operator/Menu Echo
[0,1]
1
-
32
Message
Message type
[0,9]
9
-
50
Message min speed
[1, 200]
8
Selected speed unit**
51
Message max speed
[1, 200]
200
Selected speed unit**
52
Message direction
[0, 1, 2]
2
OUT: 0 | IN: 1 | BIDIR: 2 53
Message min range
[5, 180]
15
m*
54
Message max range
[5, 180]
180
m*
55
Track selection
[0,3]
0
56
Contacts K1 and K2
Contact min speed
[1, 200]
4, 50
Selected speed unit**
61, 81 (K1, K2)
Contact max speed
[1, 200]
200, 200
Selected speed unit**
62, 82 (K1, K2)
Contact direction
[0, 1, 2]
1, 1
OUT: 0 | IN: 1 | BIDIR: 2 63, 83 (K1, K2)
Contact min range
[5, 180]
5, 15
m*
64, 84 (K1, K2)
Contact max range
[5, 180]
180, 180
m*
65, 85 (K1, K2)
Contact active duration [56, 65535 1000, 1000 ms
67, 87 (K1, K2)
Contact idle state
[0, 1]
1, 1
-
69, 89 (K1, K2)
* The distance is always given in meters (m).
** The minimum radial speed for target validation is 3.5 km/h.
*** The S/N field and the “Chosen value” column allow you to note the configuration chosen for a given serial number.
2.2.1
Hardware parameters
2.2.1.1
Configuration mode ([pnum] 4)
Description
Radar configuration mode
Notes
•
0 : through rotary encoders
•
1 : through RS-232
Changing this setting immediately causes the current settings to be saved and the radar to be
reset.
If the position of one of the rotary encoders is changed, the configuration mode returns to
"rotary encoders"
with default parameters values
.