![Icom UT-111 Скачать руководство пользователя страница 3](http://html2.mh-extra.com/html/icom/ut-111/ut-111_instructions_3798971003.webp)
The trunking unit may be installed to IC-F320S and
IC-F420S, however, we do not recommend this due
to channel capacity.
D
IC-F300 and IC-F400 series instructions
q
Turn power OFF, then disconnect the DC power
cable.
w
Unscrew the 4 screws, then remove the bottom
cover.
e
Unscrew the 2 screws, then remove the front panel.
r
Unscrew the 3 screws and remove the flat cable,
then remove the FRONT unit.
t
For the IC-F400 series transceiver, connect 2 points
on the FRONT and MAIN units with a jumper wire
as shown below.
This modification is not required when the trans-
ceiver’s serial number is over 60000.
y
Connect JP2 on the UT-111 by soldering as shown
on p. 5.
u
When using the UT-111 with IC-F410/S or
IC-F420/S, MAIN unit modification is necessary.
i
Plug the UT-111 to J2 (IC-F300 series) or J4
(IC-F400 series) on the MAIN unit.
o
Reassemble the transceiver.
IC-F300/F400 SERIES PC BOARD MODIFICATION
D
FRONT and MAIN units modification
Connect 2 points with a jumper wire as shown below.
• FRONT unit
16
J2 or J4
Jumper wire
pin 21
- 3 -
• MAIN unit
NOTE: The MAIN unit shows the IC-F400 series transceiver.