INSTRUCTIONS
GPS RECEIVER
MXG-5000
Thank you for purchasing the
MXG-5000
gps
receiver
.
Please read these instructions thoroughly
before installing and operating the GPS
receiver.
PRECAUTIONS
For CLASS A UNINTENTIONAL RADIATORS
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
CAUTION: NEVER
immerse the GPS receiver
in water. The GPS receiver meets IPX6 require-
ments for high-pressure water jet resistance.
However, once it has been dropped, high-pres-
sure water jet resistance cannot be guaranteed
because of possible damage to its case or the
waterproof seal.
DO NOT
use or place the GPS receiver in
areas with temperatures below –20°C (–4°F)
or above +60°C (+140°F).
DO NOT
use chemical agents such as benzine
or alcohol when cleaning, as they can damage
the GPS receiver’s surfaces.
The GPS receiver is only for the specified Icom
equipment such as MarineCommander
™
or
MA-500TR! —Other manufacturer’s equip-
ment may have different pin assignments and
can damage the equipment or GPS receiver if
attached.
Item
Qty.
q
Hose clamp (HAS-40) .......................... 2
w
Extension pipe (2273 pipe) .................. 1
e
GPS receiver ........................................ 1
FCC INFORMATION
CAUTION:
Changes or modifications not
expressly approved by the party responsible
for compliance could void the user’s authority
to operate the equipment.
CE Versions of the MXG-5000
which display the “CE” symbol on
the serial number seal, comply
with the essential requirements of the Euro-
pean Radio and Telecommunication Termi-
nal Di rective 1999/5/EC.
This warning symbol indicates that
this equipment operates in non-
harmonised frequency bands and/
or may be subject to licensing conditions in
the country of use. Be sure to check that
you have the correct version of this radio or
the correct pro gramming of this radio, to
comply with na tional licensing requirement.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) this device may not cause harm-
ful interference, and (2) this device must ac-
cept any interference received, including inter-
ference that may cause undesired operation.
SUPPLIED ACCESSORIES
• Power supply voltage : 4.75 to 5.25 V DC
(supplied from the connected equipment)
• Operating temp. range : −20˚C to +60˚C;
−4˚F to +140˚F
• Relative humidity
: Less than 95%
(at +35˚C; +95˚F)
• Dimensions
:
140(d)
×
157.2(H)
mm;
5
1⁄2
(d)
×
6
3⁄16
(H) in.
• Weight (approx.)
: 710 g; 1.57 oz
• Cable length (approx.) : 10 m; 32 ft. 9
3⁄4
in.
• Receiving frequency : 1575.42 MHz
• Receiving channels : 12
• Receiving codes
: L1, C/A-code, SPS
• Satellite differential type
:
WAAS, EGNOS, MSAS
• TTFF (Time to First Fix)
: 40 sec. (typical)
SPECIFICATIONS
All stated specifications are subject to change without notice or obligation.
q
w
e
ABOUT CE
DECLARATION
OF CONFORMITY
We Icom Inc. Japan
1-1-32, Kamiminami, Hirano-ku
Osaka 547-0003, Japan
Kind of equipment:
Type-designation:
Signature
Authorized representative name
Place and date of issue
Version (where applicable):
0560
Y. Furukawa
General Manager
Icom (Europe) GmbH
Communication Equipment
Auf der Krautweide 24,
65812 Bad Soden am Taunus,
Germany
GPS RECEIVER
mxg-5000
2nd Dec. 2010
Bad Soden
Declare on our sole responsibility that this equipment complies with the
essential requirements of the Radio and Telecommunications Terminal
Equipment Directive, 1999/5/EC, and that any applicable Essential Test
Suite measurements have been performed.
This compliance is based on conformity with the following harmonised
standards, specifications or documents:
IEC 61108-1:2003
EN 60945:2002
EN 60950-1 2006 A11:2009
i)
ii)
iii)
iv)
v)
vi)