37
DSC OPERATION
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D
Receiving a Test call
1. Push
ALARM OFF
to turn OFF the alarm.
2.
Pushthesoftwarekeybelowyournextoperation.
IGN
(Ignore)
•Ignores the call and returns to the operating screen.
• The call is saved in the DSC Log.
•“ ” blinks continuously until you display the call message.
ABLE
(Able to Comply)
•
SendstheAcknowledgement“AbletoComply.”
• The call is saved in the DSC Log.
ACPT
(Accept)
• Accepts the call.
•
Displaysthereceivedcall’s
information.
• The call is saved in the DSC Log.
• Push
ACK
, and then push
CALL
to
sendaTestAcknowledgementcall.
(p.30)
• Push
RESEND
to resend.
NOTE
:IftheAutoACKfunctionissetto“Auto,”theTest
Acknowledgementcallisautomaticallysenttothecalling
stationwhenthecallisreceived.(p.42)
When a Test call is received:
•The alarm sounds for 2 minutes.
•“RCVD TEST CALL” is displayed.
TIP:
Bydefault,theAutoACKfunctionautomatically
sendsanAcknowledgementtothecallingstation(p.42)
.
Ifthefunctionissetto“Manual,”thefollowingscreensare
displayed.