6
30
REPEATER SETTINGS
2001 NEW
n
Frequency setting for ID-RP4000V
NOTE:
The ID-RP4000V connection may not be recog-
nized by the PC depending on the length of the
USB cable. Using as short a USB cable as possible
is recommended.
q
Start up the PC.
w
Connect a USB cable
(A-B type; purchase separately)
between PC’s USB port and ID-RP4000V [SER-
VICE T] or [SERVICE R] connector, then turn the
ID-RP4000V power ON.
• Connect a USB cable to [SERVICE R] when setting re-
ceive frequency.
• Connect a USB cable to [SERVICE T] when setting
transmit frequency.
e
Start up the ID-RP4000V utility.
Double click the “ID-RP4000V” icon on the desktop
or select the “ID-RP4000V” in “Program” in “Start”
menu.
r
The screen as at left appears, then the dialog
below is displayed.
• Click [OK].
NOTE:
The screen, described in steps
t
, appears
instead of these screens when the correct COM
port number is set.
• Click <Option (O)> menu then select <COM Port(P)…>.
Enter the allocated number of the ID-RP4000V [SER-
VICE T/R] connector then click [Apply] in the displayed
“COM Port Setting” screen.
Enter the COM port number.
Click
NOTE:
See pages 22 to 24 for the COM port num-
ber confirmation details.
q
Enter the speci-
fied frequency.
w
Click
t
The utility reads the ID-RP4000V setting and the
screen as at left appears when the correct COM
port number is set.
y
Enter the specified receive and transmit frequen-
cies into “RX/TX Frequency” column.
u
Click [Write] to program the set frequencies into
the ID-RP4000V.