background image

2001 NEW

UHF DIGITAL VOICE REPEATER

 

id- rp4000v

Instruction Manual

This device complies with Part 15 of the FCC rules. Operation 
is subject to the following two conditions: (1) This device may 
not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause 
undesired operation.

Содержание ID-RP4000V

Страница 1: ... device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Страница 2: ... wire or other ob jects touch any internal part or connectors on the ID RP4000V This may result in an electric shock CAUTION NEVER operate or touch the ID RP4000V with wet hands This may result in an elec tric shock or damage to the ID RP4000V CAUTION NEVER expose the ID RP4000V to rain snow or any liquids DO NOT use or place the ID RP4000V in areas with temperatures below 10 C 14 F or above 50 C ...

Страница 3: ...r w e q t qPower cable OPC 1309 approx 1 m 3 3 ft 1 wControl cable OPC 1069 1 eRubber feet 4 rSpare fuses FGB10A 2 tUtility CD 1 FOR CLASS B UNINTENTIONAL RADIATORS This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residenti...

Страница 4: ...C is performed in the ID RP4000V thus the ID RP4000V receives and transmits 4 8 kbps serial data only Different frequencies are used for each transmis sion and reception in semi duplex mode The ID RP4000V utility software supplied with the ID RP4000V and a PC are required for both re ceive and transmit frequency settings Zone Area Signal Internet Antenna ID RP2L POWER 10 BESE T SERVICE 1 SERVICE 2...

Страница 5: ...ct a PC via a USB cable A B type purchase separately to set the receive frequency q w e r t n Rear panel q RECEIVE ANTENNA CONNECTOR RX ANT p 5 Connect a 440 MHz band antenna through a du plexer w TRANSMIT ANTENNA CONNECTOR TX ANT p 5 Connect a 440 MHz band antenna through a du plexer e COOLING FAN r POWER CONNECTOR DC13 8V p 5 Connect to the ID RP2C via the supplied DC power cable OPC 1309 to be ...

Страница 6: ...enly Strip the cable and fold the braid back over the clamp Soft solder the center conductor Install the center conductor pin and solder it Carefully slide the plug body into place aligning the center conductor pin on the cable Tighten the nut onto the plug body r e 15 mm 3 mm 6 mm No space Solder hole Be sure the center conductor is the same height as the plug body Clamp Center conductor Washer N...

Страница 7: ... the ID RP4000V as shown at left when you do not install the ID RP4000V in the 19 inch rack Desktop opera tion can be performed n Grounding To prevent electrical shock television interference TVI broadcast interference BCI and other prob lems ground the transceiver through the GROUND terminal on the rear panel For best results connect a heavy gauge wire or strap to a long earth sunk copper rod Mak...

Страница 8: ...D RP2C to AH 106 107 to AH 106 107 OPC 1309 supplied w ID RP4000V Control cable supplied w ID RP4000V ID RP2L Assist 1 430 440 MHz band antenna purchase separately ID RP2L Assist 2 AC outlet AC power cable External DC power supply 13 8 V Black _ Red Coaxial cables purchase separately Not available in European countries as of May 2010 ...

Страница 9: ...example NOTE The ID RP4000V connection may not be recog nized by the PC depending on the length of the USB cable Using as short a USB cable as possible is recommended n Microsoft Windows XP Service Pack 2 q Start up Windows Quit all applications if activated w Insert the CD supplied with the ID RP4000V into the CD drive e Connect the PC and ID RP4000V SERVICE T connector using with a USB cable A B...

Страница 10: ... click Next u The wizard starts searching for the driver and shows the dialog as at left during search Click i While searching the driver the Hardware Installa tion dialog box appears as at left Click Continue Anyway to start the installation NOTE If the dialog as at left does not appear select Install from a list or specific location Ad vanced in step y then select the driver folder in the CD ...

Страница 11: ... Click 0 After the installation is completed click Finish 1 After clicking Finish Found New Hardware USB Serial Port appears as at left Click Select 2 The Found New Hardware Wizard will come up as at left Select No not this time then click Next Continue to the next page ...

Страница 12: ...d starts searching for the driver and shows the dialog as at left during search Click 5 While searching the driver the Hardware Installa tion dialog box appears as at left Click Continue Anyway to start the installation NOTE If the dialog as at left does not appear select Install from a list or specific location Ad vanced in step 3 then select the driver folder in the CD ...

Страница 13: ...rts installing the USB driver Click 7 After the installation is completed click Finish 8 After clicking Finish Found New Hardware Your new hardware is installed and ready to use ap pears as at left 9 Eject the CD Rebooting the PC is recommended ...

Страница 14: ...Connect the PC and ID RP4000V SERVICE T connector using with a USB cable A B type pur chase separately r Found New Hardware ID RP4000V SERVICE T appears as at left Click t The Found New Hardware Wizard will come up as at left Click Next Click Select y When the dialog box as at left is displayed select Search for a suitable driver for my device recom mended then click Next ...

Страница 15: ...lick i When the appropriate driver is found the dialog box appears as at left appears Click Next to start the installation Click o After the installation is completed click Finish 0 After clicking Finish Found New Hardware USB Serial Port appears as at left Continue to the next page ...

Страница 16: ... Windows 2000 continued Click 1 The Found New Hardware Wizard will come up as at left Click Next Click Select 2 Select Search for a suitable driver for my device recommended then click Next Click Select 3 Select CD ROM drives then click Next ...

Страница 17: ...S Click 4 When the appropriate driver is found the dialog box appears as at left appears Click Next to start the installation Click 5 After the installation is completed click Finish 6 Eject the CD Rebooting the PC is recommended ...

Страница 18: ...pe pur chase separately Click r The Add New Hardware Wizard will come up as at left Click Next Click Select t When the dialog box as at left is displayed select Search for the best driver for your device Rec ommended then click Next Click Select y Click to add the check mark 4 into Specify a lo cation then click Browse NOTE Remove the check mark 4 from Floppy disk drive CD ROM drive and Micro soft...

Страница 19: ...r folder then select WinME98 folder in the CD Click OK Click Confirm i Confirm the driver folder in the CD is selected then click Next Click o When the driver is found the screen as at left ap pears Click Next to start the driver installation Continue to the next page ...

Страница 20: ...n Microsoft Windows 98SE Me continued Click 0 After the installation is completed click Finish 1 After clicking Finish New Hardware Found ICOM ID RP4000V SERVICE T appears as at left 2 Eject the CD Rebooting the PC is recommended ...

Страница 21: ... a USB cable A B type pur chase separately r Found New Hardware appears as at left Click Locate and install driver software recom mended t In case User Account Control dialog box appears as at left click Continue y When the dialog box as at left is displayed click Next Continue to the next page Click Click When the PC can be connected to the Internet please make the PC stand alone Click 4 DRIVER I...

Страница 22: ...layed Click Install this driver software anyway to start the installation Click i The wizard starts searching for the driver and shows the dialog as at left during search o After the installation is completed click Close Click n Microsoft Windows Vista continued ...

Страница 23: ...rt appears as at left click Next 1 The dialog box as at left is displayed Click Install this driver software anyway to start the installation Click 2 The wizard starts searching for the driver and shows the dialog as at left during search Continue to the next page Click ...

Страница 24: ...21 4 DRIVER INSTALLATION n Microsoft Windows Vista continued 3 After the installation is completed click Close 4 Eject the CD Rebooting the PC is recommended Click ...

Страница 25: ...Windows XP Click Click r System Properties screen appears as at left Click Hardware tub and then click Device Man ager Click t Device Manager screen appears Click of Ports COM LPT Check the connected unit and connector names and COM port number In this example the USB serial port number is 3 y Confirm ICOM ID RP4000V SERVICE T COMQ is displayed If not displayed or few COM port numbers are dis play...

Страница 26: ...k the connected unit and connector names and COM port number In this example the USB serial port number is 3 y Confirm ICOM ID RP4000V SERVICE T COMQ is displayed If not displayed or few COM port numbers are dis played at the same time the driver installation may not be installed properly Un install the USB driver then re install the driver again in such cases NOTE Q is the COM port number that is...

Страница 27: ...ontinue y Device Manager screen appears Click of Ports COM LPT Confirm ICOM ID RP4000V SERVICE T COMQ is displayed If not displayed or few COM port numbers are dis played at the same time the driver installation may not be installed properly Un install the USB driver then re install the driver again in such cases NOTE Q is the COM port number that is used for the communication setting with the uti...

Страница 28: ... the CD drive e Open the CD drive directory using My Computer or Explorer Contents of the CD are displayed Double click r Double click the Driver and then the appropriate folder for your OS to open and display the folder contents Click t Run the appropriate exe file according to the OS For Windows XP 2000 ICOM_UNIN_NT EXE For Windows 98SE Me ICOM_UNIN_9x EXE Click Click y The un installer starts a...

Страница 29: ...nstall t Click to add the check mark 4 into Delete the driver software for this device then click OK y Right click the ICOM ID RP4000V SERVICEQ then select Uninstall u Click to add the check mark 4 into Delete the driver software for this device then click OK NOTE Un install the USB drivers for ID RP4000V SERVICE R with the same manner Manual un installation from each unit and connector is needed ...

Страница 30: ...n dows operating system n Installation q Start up Windows Quit all other applications if running w Insert the CD supplied with the ID RP4000V into the CD drive e Displays the contents of the CD using with the My Computer or Explorer Double click r Double click IDRP4KV folder Contents of the folder are displayed Double click t Double click Disk1 folder Contents of the folder are displayed Double cl...

Страница 31: ...tion click Next When installing into a different location click Browse select the desired location and then click Next 0 Starts the utility installation Click 1 InstallShield Wizard Complete screen appears when the installation is finished Click Finish to complete the installation 2 Eject the CD from the CD drive then reboot the PC ...

Страница 32: ...s as follows q Open Control Panel in the Start menu Click w Click Add or Remove Programs Click Select e Select Icom ID RP4000V then click Change Re move Click r Confirm Uninstall screen appears click OK t The screen at left appears when the un installation starts Click y The screen at left appears when the un installation is completed Click Finish ...

Страница 33: ...elect the ID RP4000V in Program in Start menu r The screen as at left appears then the dialog below is displayed Click OK NOTE The screen described in steps t appears instead of these screens when the correct COM port number is set Click Option O menu then select COM Port P Enter the allocated number of the ID RP4000V SER VICE T R connector then click Apply in the displayed COM Port Setting screen...

Страница 34: ...ved PC does not recognize the ID RP4000V The settings cannot be programmed into the ID RP4000V properly POSSIBLE CAUSE Power connector has a poor contact Blown fuse Antenna or coaxial cable has problems Antenna or coaxial cable has problems The repeater controller ID RP2C setting is wrong Too long USB cable is used Too long USB cable is used SOLUTION Check the connector pins and re connect the DC ...

Страница 35: ...V DC High 23 30 W Low 2 3 W Modulation system Quadrature 244 8 MHz Occupied bandwidth Less than 5 5 kHz Spurious emissions Less than 60dB D Receiver Receive system Double conversion superheterodyne Intermediate frequencies 1st 70 0 MHz 2nd 455 kHz Sensitivity BER 1 10 2 Less than 0 45 µV Adjacent channel selectivity More than 65 dB 20 kHz offset Intermodulation rejection ratio More than 65 dB 20 k...

Страница 36: ...Suite measurements have been performed Versions of the ID RP4000V which display the CE symbol on the serial number label comply with the essential requirements of the European Radio and Telecommunica tion Terminal Directive 1999 5 EC This warning symbol indicates that this equipment operates in non harmonised fre quency bands and or may be subject to li censing conditions in the country of use Be ...

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ...n A 6448H 1EX e Printed in Japan 2006 2010 Icom Inc 31 Europe Intended Country of Use n AT n BE n CY n CZ n DK n EE n FI n FR n DE n GR n HU n IE n IT n LV n LT n LU n MT n NL n PL n PT n SK n SI n ES n SE n GBn IS n LI n NO n CH n BG n ROn TR n HR ...

Отзывы: