6-7
6-3 FREQUENCY VERIFICATION
†
The output level of the signal source is measured at the load end (PD).
ADJUSTMENT
ITEM NAME
REPEATER’S
CONDITION
OPERATION
VALUE
REFERENCE
FREQUENCY
-Adjustment (Auto)-
1
[REF OSC1]
• Receiving
• Connect the 10 MHz reference frequency
source to the [REF IN 10 MHz] connector,
and set it to:
Frequency: 10.000000 MHz
Level
†
:
+97 dBµV (–10 dBm)
Modulation: None
• Push the PC's [ENTER] key.
“OK” is displayed
in the Result row.
6-4 RECEIVE VERIFICATIONS
†
The output level of the standard signal generator (SSG) is measured at the load end (PD).
6-5 RESTARTING THE REPEATER
1) Click [Stop],then perform the All Reset on the ID-RP3 ADJ window.
2)
Turn OFF the repeater.
ADJUSTMENT
ITEM NAME
REPEATER’S
CONDITION
OPERATION
VALUE
RECEIVE
SENSITIVITY
-Adjustment (Auto)-
1
[Total Gain VHF
PRE ON ref]
• Receiving
• Connect the SSG to the [RX ANT]
connector, and set it to:
Frequency: 146.0215 MHz
Level
†
:
+30 dBµV (–77 dBm)
Modulation: None
• Push the PC's [ENTER] key.
“OK” is displayed in
the Result row.
2
[Total Gain VHF
PRE ON set]
• Set the SSG output as:
Level
†
: OFF
• Push the PC's [ENTER] key.
3
[VHF AGC set]
• Set the SSG output as:
Level
†
:
+50 dBµV (–57 dBm)
• Push the PC's [ENTER] key.