manualshive.com logo in svg
background image

PC to IC-R8600

IC-R8600 to PC

OK message to PC

NG message to PC

Reading command format:

Send a request command from the PC to request to return an IC-R8600 setting value.

A reading command is composed of only a command number.

The IC-R8600 will return the requested setting value as an acknowledgement when receiving the command.

If the request command is invalid, “NG (FA)” will be returned as the acknowledgement.

 

Control commands

 

D

Command format (Continued)

q

w

e

r

t

i

o

F

E

F

E

9

6

E

0

F

D

F

F

×

×

×

×

Preamble

IC-R8600

address

PC

address Command

Padding

Postamble

1 byte

(Variable)

Sub

command

q

e

w

r

t

y

i

o

F

E

F

E

9

6

E

0

F

D

F

F

×

×

×

×

…………

Preamble

PC

address

IC-R8600

address Command

Padding

Sub

command

Data area

Postamble

1 byte

(Variable)

(Variable)

q

e

w

u

i

F

E

F

E

E

0

9

6

F

A

F

D

Preamble

PC

address

IC-R8600

address

Postamble

NG

code

 

Command (PC to IC-R8600)

 

Acknowledgement to a valid command (IC-R8600 to PC)

 

Acknowledgement to an invalid command (IC-R8600 to PC)

NOTE: When the data length is an odd number

Every command’s total length in byte must be an even number.

If the total length is an odd number, you need to add an extra “FF” at the end of the packet, to make the length an 

even number. In the same manner, the length of the acknowledgement data from the IC-R8600 is an even number.

FE FE

FF

FF

96

E0

Cn

Sc

Data area

FD

Preamble code (fixed)

IC-R8600’

s address

(fixed)

PC’

s default address

(“

E0” 

in Acknowledgement)

Command number

(see the command table)

Sub command number (may not necessary

See command table.)

BCD code data for frequency or setting

 entry

End of message Postamble (fixed)

Padding

(See the note below)

FE FE E0

96

FB

FD

FE FE E0

96

FA

FD

Preamble code (fixed)

PC’

s address (fixed)

IC-R8600’

s address 

(fixed)

OK code

(fixed)

End of message Postamble (fixed)

NG code (fixed)

q

q

w

w

e

e

r

t

y

i

i

u

q

w

e

i

u

o

o

FE FE E0

96

Cn

Sc

Data area

FD

q

w

e

r

t

y

i

I/Q SIGNAL

8

Содержание IC-R8600

Страница 1: ...I Q OUTPUT REFERENCE GUIDE iR8600 COMMUNICATIONS RECEIVER...

Страница 2: ...Q data details 5 D D 24 bit long I Q data 5 D D 16 bit long I Q data 5 D D Remarks 6 Control commands 7 D D General description 7 D D Command format 7 Usable control commands 9 D D Command descriptio...

Страница 3: ...DR You can download it from the Icom web site The software is commonly used with HDSDR An SDR receive software freeware You can download it from http www hdsdr de I Q signal specifications Sampling fr...

Страница 4: ...nd control the IC R8600 through the WinUSB using an I Q receive software user supplied To use WinUSB you need to set the driver s GUID and appropriate endpoint Refer to the next topic for details abou...

Страница 5: ...to be followed by a I signal LThe data format I Q data and synchronous data differs depending on the bit depth 16 bit or 24 bit p 5 About the I Q signals Address Hexadecimal Direction Endpoint Number...

Страница 6: ...es and 0x8000 2 bytes The Synchronous data is inserted into the I Q data at the following rate The Synchronous data is inserted into the I Q data at the following rate I Q data details Sampling rate S...

Страница 7: ...as a constant frequency component positioned at the center frequency 0 Hz A lower sampling frequency makes the DC component level greater An example of the DC component that is monitored on the HDSDR...

Страница 8: ...ommand The IC R8600 will return the result as an acknowledgement after receiving a command LThe control command format is based on the ICOM Communication Interface V CI V format LThere are 2 command t...

Страница 9: ...ommand PC to IC R8600 Acknowledgement to a valid command IC R8600 to PC Acknowledgement to an invalid command IC R8600 to PC NOTE When the data length is an odd number Every command s total length in...

Страница 10: ...the RF Gain 0000 Minimum 0255 Maximum BCD value Not usable Usable 16 02 00 01 Send read the PRE AMP setting 00 OFF 01 ON Not usable Usable 65 00 01 Send read the IP function status 00 OFF 01 ON Not us...

Страница 11: ...readable capacity NG FA will be returned To read the number of the edge send command 1A 0E The Read Receive Band Edge Count command IC R8600 to PC Read data format q w e r t y u i o 0 1 2 X X X X X X...

Страница 12: ...nal output setting by sending the command through the I Q OUT port Only when the I Q mode is set to ON you can set the I Q output to ON When the sent command is valid and accepted by the IC R8600 the...

Страница 13: ...When the I Q signal output is ON I Q output setting Sampling frequency Bit depth 1 ON 0 Fixed 0 X 0 X 0 1 LAlso the bit depth and sampling frequency are returned I Q Output Bit depth Sampling frequen...

Страница 14: ...ode the receive mode is fixed to USB and AGC is forcibly turned OFF Audio output Audio output from the internal speaker external speaker terminal and headphone terminal are muted The audio output from...

Страница 15: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A7375 11EX 2018 Icom Inc...

Отзывы: