5 - 3
ADJUSTMENT
RECEIVER’S
CONDITION
OPERATION
ADJUSTMENT
ITEM
VALUE
BAR
ANTENNA
(0.495 MHz)
1
NOTE:
This procedure (the step "1" and "2") must be done
twice
.
• Frequency: 0.495 MHz
• Receiving
1) C o n n e c t t h e s u p p l i e d a n t e n n a
to a signal generator through an
appropriate conector adapter, and set
it as follows;
Frequency
: 0.495 MHz
Level
: 107 dBµ (0 dBm)
Modulation
:
None
2) Gradually move the IC-R6 away from
the SG until the 11th scale of the
signal strength indicator on the IC-R6
LCD disappears.
3) Push
[V/M]
when the 11th scale just
disappears.
Push
[V/M]
(the 11th
scale is just
disappeared)
(1.620 MHz)
2
• Frequency: 1.620 MHz
• Receiving
1) Set the SSG as;
Frequency
: 1.620 MHz
2) Follow the same procedure as the
step "1."
5-3 RECEIVE ADJUSTMENTS
1) Select an adjustment item using
[BAND]
/
[TS]
.
2) Set the SSG as specifi ed, then push
[V/M]
when the 11th scale is just disappeared, to store the adjustment value.
STANDARD SIGNAL GENERATOR
Supplied antenna
Push [V/M] when the 11th scale just disappears.
Conector adaptor
Just disappeared.
¤
ADJUSTING BAR ANTENNA