5 - 7
SOFTWARE ADJUSTMENTS–Continued
S-METER
[S-M]
(2510.1 MHz
FM mode)
(2510.1 MHz
WFM mode)
21
22
• Mode
: FM
• Connect an SSG to the antenna connector and set as
Level
: 0.56 µV* (–112 dBm)
Frequency
: 2510.1 MHz
Modulation
: ±1 kHz
Deviation
: ±3.5 kHz
• Receiving
• Mode
: WFM
• Connect an SSG to the antenna connector and set as
Level
: 32 µV* (–77 dBm)
Deviation
: ±52.5 kHz
• Receiving
• Push
[8 SET]
key.
• Push
[8 SET]
key.
ADJUSTMENT
ADJUSTMENT CONDITION
OPERATION
*This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.