CONTROL COMMANDS
12
73
■
General
The IC-R10 can be connected to a PC via the PC’s RS-232C
port using an optional CT-17
CI-V LEVEL CONVERTOR
. This
allows you to control the receiver from the PC and/or transfer
data from the receiver to the PC.
Control is provided via Icom’s CI-V Communication Interface.
■
Data format
The CI-V system can be operated using the following data
formats. Data formats differ according to command numbers.
A data area is added for some commands.
Controller
➡
IC-R10
IC-R10
➡
Controller
q
Preamble code (fixed)
w
Receiver’s default address
e
Controller’s default address
r
Command number (see table below)
t
Sub command number (see table below)
y
BCD code data for frequency entry
u
End of message code (fixed)
■
Command table
FE
FE
52
E0
Cn
Sc
Data area
FD
q
w
e
r
t
y
u
FE
FE
E0
52
Cn
Sc
Data area
FD
q
e
w
r
t
y
u
Description
Cn
Sc
Transfers frequency data (transceive)
00
—
Transfers mode data (transceive)
01
—
Reads display frequency
03
—
Reads display mode
04
—
Sets frequency data
05
—
Sets LSB mode
06
00
Sets USB mode
01
Sets AM mode
02
Sets CW mode
03
Sets FM mode
05
Sets WFM mode
06
Reads squelch condition (open or closed)
15
01
Reads S-meter level
02