5 - 1
SECTION 5. ADJUSTMENT
PROCEDURE
¤
CONNECTION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
Cloning software
CS-M24/M23 ADJ (Revision 1.0 or later)
Cables
OPC-478UC and OPC-2091
RF power meter
(50
Ω
terminated)
Measuring range
: 0.1–6 W
Frequency range
: 100–300 MHz
SWR
: Less than 1.2 : 1
Frequency counter
Frequency range
: 0.1–300 MHz
Frequency accuracy : ±1 ppm or better
Input level
: Less than 1 mW
Standard signal
generator (SSG)
Frequency range
: 0.1–300 MHz
Output level
: –20 dBµ to 90 dBµ
(–127 to –17 dBm)
¤
REQUIRED EQUIPMENTS
5-1 PREPARATION
to the antenna connector
RF power meter
0.1–6 W/50
Ω
Frequency
counter
Standard signal generator
–20 to 90 dBµ
(–127 dBm to –17 dBm)
DO NOT
transmit while
an SSG is connected to
the antenna connector.
To [DC]
PC
to USB port
OPC-478UC
(USB type)
OPC-2091