background image

i

IMPORTANT

READ ALL INSTRUCTIONS

 carefully and com-

pletely before using the transceiver.

SAVE THIS INSTRUCTION MANUAL —

 This 

instruction manual contains important operating instructions 
for the 

IC-F3161T/S/DT/DS, IC-F3163T/S VHF TRANSCEIV-

ERS

 and 

IC-F4161T/S/DT/DS, IC-F4163T/S UHF TRANS-

CEIVERS

.

See the operating guide for details of IDAS™, BIIS, MDC 
and LTR

®

 system operations. Ask your dealer for details.

EXPLICIT DEFINITIONS

WORD

DEFINITION

R

DANGER!

Personal death, serious injury or an explo-
sion may occur.

R

WARNING!

Personal  injury,  fire  hazard  or  electric 
shock may occur.

CAUTION

Equipment damage may occur.

NOTE

If disregarded, inconvenience only. No risk 
of personal injury, fire or electric shock.

Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incor-
porated (Japan) in Japan, the United States, the United Kingdom, Germany, 
France, Spain, Russia and/or other countries.
IDAS is trademark of Icom Incorporated (Japan).
LTR  is  a  registered  trademark  of  the  E.F.Johnson Technologies,  INC.  in  the 
United States.
All other products or brands are registered trademarks or trademarks of their 
respective holders.

Содержание IC-iF3161

Страница 1: ...lies with Part 15 of the FCC Rules Op eration is subject to the condition that this device does not cause harmful interference The photo shows the UHF transceiver iF4161 F4163 UHF TRANSCEIVER Series i...

Страница 2: ...l death serious injury or an explo sion may occur RWARNING Personal injury fire hazard or electric shock may occur CAUTION Equipment damage may occur NOTE If disregarded inconvenience only No risk of...

Страница 3: ...ansmit DO NOT use or place the transceiver in direct sunlight or in areas with temperatures below 22 F 30 C or above 140 F 60 C The basic operations transmission and reception of the transceiver are g...

Страница 4: ...nce by one or more of the following meas ures Reorient or relocate the receiving antenna Increase the separation between the equipment and re ceiver Connect the equipment into an outlet on a circuit d...

Страница 5: ...annel selection 12 Call procedure 13 Receiving and transmitting 13 User set mode 16 Scrambler function 16 Stun function 16 Emergency transmission 17 Man Down Emergency Call 17 Automatic Key Lock funct...

Страница 6: ...ector cover with screw Flexible antenna This illustration is for the UHF type Accessory attachments D Flexible antenna Connect the supplied flexible antenna to the antenna connector CAUTION NEVER HOLD...

Страница 7: ...tach the battery pack when the trans ceiver is wet or soiled This may result water or dust get ting into the transceiver battery pack and may result in the transceiver being damaged q w Battery releas...

Страница 8: ...n the screw q w Multi connector Connector cover CAUTION Attach the connector cover when the optional equipment is not used Otherwise the terminals of the multi connec tor may be shorted by metal objec...

Страница 9: ...mmed by your dealer p 6 t PTT SWITCH PTT Push and hold to transmit release to receive y DEALER PROGRAMMABLE KEYS Side2 Side3 Desired function can be programmed independently by your dealer p 6 u 10 KE...

Страница 10: ...power ON OFF and adjusts the audio level Function display SET CALA TXCU TXC q t i u y r e w o 0 q SIGNAL STRENGTH INDICATOR Indicates relative signal strength level w LOW POWER INDICATOR Appears when...

Страница 11: ...mode 0 KEY INDICATOR Indicate the programmed function of the front panel keys P0 P1 P2 and P3 Programmable function keys The following functions can be assigned to EMR Side1 Side2 Side3 P0 P1 P2 and P...

Страница 12: ...eriod has passed Push and hold this key for 1 sec to indicate the scan list then push CH Up or CH Down to select the desired list SCAN ADD DEL TAG KEY SCAD Push to add channel to or delete it from the...

Страница 13: ...r and OPT 1 2 3 Push and hold for 1 sec again to turn the lock function OFF LONE WORKER KEY LONE Push to turn the Lone Worker function ON or OFF If the Lone Worker function is activated the Emergency...

Страница 14: ...l transmission is necessary before you call another station depending on your signaling system Call A and or Call B may be available when your system employs selective Individual Group calls Ask your...

Страница 15: ...o toggle the encryption transmission function ON and OFF COMPANDER KEY COMP Push to toggle the compander function ON and OFF The compander function reduces noise components from the transmitting audio...

Страница 16: ...1 P2 P3 e When the PASSWORD indication does not clear after inputting 6 digits the input code number may be incorrect Turn the power off and start over in this case D Battery type selection The batter...

Страница 17: ...mmed 16 zones can be selected D Voting operation The transceiver automatically starts scanning when a zone specified for the voting operation is selected The voting scan detects the S meter of the rep...

Страница 18: ...for accessory attachments Receiving q Rotate VOL to turn the power ON w Push CH Up or CH Down or rotate ROTARY SELEC TOR to select the conventional system channel in se quence Depending on the pre set...

Страница 19: ...ermined by the penalty timer D TX code channel selection If the transceiver has TX Code CH Select assigned to it the indication can be toggled between the operating channel number or name and TX code...

Страница 20: ...CH Select to set Return to the stand by mode i Push Call to transmit USING TX CODE ENTER KEY q After pushing TX Code CH Select push CH Up or CH Down or push TX Code CH Up or TX Code CH Down to select...

Страница 21: ...he key assigned for user set mode User Set Mode allows for the quick item selection Set En able for the often used items in the CS F3160 F5060 clon ing software Ask your dealer for details NOTE Side2...

Страница 22: ...ur dealer for details D NOTES Depending on the presetting the following functions are auto matically activated Ask your dealer for details Auto TX function After the emergency call transmission audio...

Страница 23: ...A channel automatically Turning the power ON The Priority A channel is selected each time the trans ceiver power is turned ON Status call The Priority A channel is selected when transmitting a status...

Страница 24: ...atures above 60 C 140 F High tempera ture buildup in the battery such as could occur near fires or stoves inside a sun heated car or in direct sunlight may cause the battery to rupture or catch fire E...

Страница 25: ...emperature range as below 20 C to 50 C 4 F to 122 F within a month 20 C to 35 C 4 F to 95 F within three months 20 C to 20 C 4 F to 68 F within a year D Charging caution R DANGER NEVER charge the batt...

Страница 26: ...C adapter A different type or no AC adapter is supplied de pending on the version Transceiver Battery pack Turn power OFF D Regular charging with the BC 171 The optional BC 171 provides regular chargi...

Страница 27: ...d charging with the BC 119N AD 106 The optional BC 119N provides rapid charging of the Li Ion battery pack Charging period Approx 3 hours with BP 232N The following items are additionally required AD...

Страница 28: ...se separately An AC adapter or the DC power cable OPC 656 Transceiver Battery pack AD 106 charger adapters are installed in each slot DC power cable OPC 656 Connect with the DC power supply 13 8 V at...

Страница 29: ...the direction of the arrow e then close r And hook the battery cover release hook until it makes a click sound t Fig 3 CAUTION When installing batteries make sure they are all the same brand type and...

Страница 30: ...he arrow until the base clip is locked and makes a click sound e Attach the battery pack p 2 r Clip the belt clip to a part of your belt And insert the transceiver into the belt clip until the base cl...

Страница 31: ...he battery pack if it is attached p 2 e Pinch the clip q and slide the base clip in the direction of the arrow w q w CAUTION HOLD THE TRANSCEIVER TIGHTLY WHEN HANGING OR DETACHING THE TRANSCEIVER FROM...

Страница 32: ...ty of your transmitted signal voice hold the microphone approx 5 to 10 cm 2 to 4 inches from your mouth and speak in a normal voice level To attach Attach the connector of the speaker microphone into...

Страница 33: ...pter should be pur chased separately Charging time Approx 3 hours when BP 232N is attached BC 160 desktop charger BC 145S ac adapter For rapid charging of battery pack An AC adapter is sup plied with...

Страница 34: ...ration etc HS 94 Ear hook type HS 95 Neck arm type HS 97 Throat microphone D ANTENNAS FA SC56VS FA SC57VS FA SC73US stubby antennas Shorter VHF or UHF antennas FA SC56VS Frequency range 150 162 MHz FA...

Страница 35: ...ed with a PTT switch and revolving clip VS 1SC Water protection cover PTT switch MIC VOX gain adjusting pot VOX PTT select switch VOX gain and delay adjustment q Attach the connector of the VS 1SC int...

Страница 36: ...5 sec step for a convenient interval before returning to receive 0 5 sec min default X TXC SET CALA SET TXCU TXC CALA SET TXCU TXC VOX DLY0 5 VOX DLY3 0 3 0 sec max X TXC SET Side2 Push Side3 NOTE MI...

Страница 37: ...for wireless RF exposure Belt Clip MB 93 MB 94 MB 96N and MB 96F Rechargeable Li Ion Battery Pack BP 230N and BP 232N Alkalies Battery Case BP 240 and Speaker microphone HM 131SC HM 159SC HM 169 and...

Страница 38: ...re posted to do so DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals aircraft and blasting sites Occupational Controlled Use The radio transmitt...

Страница 39: ...MEMO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Страница 40: ...1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan A 6638H 1EX r Printed in Japan 2007 2010 Icom Inc Printed on recycled paper with soy ink...

Отзывы: