4 - 8
*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
SOFTWARE ADJUSTMENT – continued
Select an operation using [CH-UP] / [CH-DN] keys, then set specified value using [RPT/BASE] / [MONI] keys on the FRONT
PANEL.
±3.0 kHz [Other]
±2.4 kHz [FRG2]
±1.5 kHz
1
2
• LCD display
: A11 LW DTCADJ
• Operating freq. : 162.2750 MHz
• No audio applied to the [MIC] connector.
• Transmitting.
• LCD display
: A13 LW RPTAF
• Operating freq : 160.2750 MHz (RX)
162.2750 MHz (TX)
• Connect a standard signal generator to
the RX antenna connector and set as:
Level
: 1 mV* (–47 dBm)
Modulation
: 1 kHz
Deviation
: ±3 kHz
[Other]
: ±2.4 kHz
[FRG2]
• Transmitting
• LCD display
: A14 LN RPTAF
• Operating freq : 160.2750 MHz (RX)
162.2750 MHz (TX)
• Transmitting
DTCS
MODULATION
BALANCE
REPEATER
DEVIATION
[WIDE]
[NARROW]
Rear
panel
Rear
panel
Connect an FM deviation meter
with an oscilloscope to the [TX]
antenna connector through an
attenuator.
Connect an FM deviation meter
to the [TX] antenna connector
through the attenuator.
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
Set to flat wave